3A-P-FS-127Z026873A-P-FS-12Thermal Laser Power Sensor, P Type, 15 µW to 3 W, Ø12 mm, 0.22-2.1 µm
4 Weeks
$1,494

规格

  • 产品名称
    3A-P-FS-12
  • 吸收器类型
    P - Short pulse
  • 窗口
    Fused Silica Window
  • 孔径尺寸
    Ø12 mm
  • 光谱范围
    220-2100 nm
  • 最小功率
    15 µW
  • 最大平均功率
    3 W
  • 最小脉冲能量
    20 µJ
  • 最大脉冲能量
    2 J
  • 响应时间
    2.5 s
  • 最大平均功率密度
    0.05 kW/cm²
  • 最大能量密度 <100 ns
    1 J/cm²
  • 最大能量密度 2ms
    1 J/cm²
  • 冷却
    Convection
  • 尺寸
    Ø70 x 19 mm
  • 电缆长度
    1.5 m
  • CE 符合性
    Yes
  • UKCA 符合性
    Yes
  • 中国 RoHS 符合性
    Yes

功能

Choosing a Thermal Sensor

In this short “Basics” video we review the use – and selection - of thermal sensors for measuring low, medium and high laser powers.

Sensors for Measuring Laser Power

In this short "Basics" video we review in general how one goes about measuring laser beam power, so that you'll have a clear understanding of what the different sensor types are, and when to use each type.

Thermal Power Sensor Accuracy

Ophir former CTO Dr. Ephraim Greenfield discusses the various factors that contribute to uncertainties in measurement when using Ophir laser power and energy meters.

Effects of Incidence Angle on Measurements

In this video, you will learn to what degree a beam’s incidence angle matters, and for which sensor types this should be taken into account.

Thermal Sensor Calibration

As the spectral sensitivity of the absorber used for the power and energy measurement is not fully linear, Ophir sensors get a high precision calibration by default with more than one wavelength.

Each thermal sensor is calibrated independently of a particular Ophir power meter with its calibration information contained in the DB15 plug. When the sensor is connected to the meter, the meter reads and interprets this information to display a calibrated reading. Each power meter is calibrated independently and has the same sensitivity as an other meter within about 2 tenths of a percent.

Unless otherwise indicated, Ophir sensors and meters should be recalibrated within 18 months after initial purchase, and then once a year after that.

Absorption of different thermal sensor absorber types

常见问题

配件

Sensor Connector to BNC Adapter

The SH to BNC Adapter allows the connection of an Ophir sensor to a current or voltage measuring device for measurement of the raw sensor analog output. A current meter should be used for photodiode sensors. Current or voltage meters can be used for thermal sensors.

对比 型号 图纸、CAD和参数 库存 价格
7Z11010BNC Adapter, DB15 Optical Sensor Connector
有库存
$92

Extended Warranty for Sensor

Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.

对比 型号 图纸、CAD和参数 库存 价格
XWAR-SENSORExtended Warranty for Sensor$450