The Nova is truly versatile for measuring power or energy from pJ and pW to hundreds of Joules and thousands of Watts. With the optional scope adapter, you can connect your pyro sensor to an oscilloscope and see every pulse up to the maximum frequency permitted by the sensor.
Offered with a two-year extended warranty
- 兼容所有标准Ophir热电堆、热释电和光电二极管传感器。
- 利用热传感器进行单次脉冲能量测量。
- 可选RS232 PC接口。可与Ophir的StarCom32应用程序一起工作。
- 功率和能量记录的图形显示和统计。
- 计算激光功率测量值平均数。
- 易于使用的软键和菜单驱动功能。 查看所有功能
Software
PC Software & Drivers
This section describes various ways to interface the Ophir meter to your PC as well as the software options available. Check out the datasheet for more details.
The StarCom application together with the Ophir meters that utilize the RS232 protocol turns your PC or laptop into a full-fledged Ophir laser power/energy meter. StarCom supports all major Ophir sensors. Supports the Nova, LaserStar, Nova-II, and Vega meters.
规格
- 产品名称Nova
- 热传感器兼容性Yes
- 光电二极管传感器兼容性Yes
- 热释电传感器兼容性Yes
- 光束跟踪传感器的兼容性No
- 统计Yes
- 模拟输出1 V
- RS23210 Hz
- 触发输入/输出No
- 板载数据存储1 k
- 自动化接口No
- Labview VI'sYes
- CE 符合性Yes
- UKCA 符合性Yes
- 中国 RoHS 符合性Yes
功能
Easy Setup of Laser Power Meter and Sensor
See how easy it is to setup an Ophir power meter and sensor to measure your laser's power and energy. Learn more at www.ophiropt.com/photonics.
Setting Your Laser Power Meter To a Custom Wavelength
Learn how to set the correct wavelength for your measurement, even when the wavelength you need is not one of the default wavelengths offered by the meter.
常见问题
- How does an energy meter measure above the maximum frequency at which it can record every pulse?答案
The energy meters will then sample at close to its maximum frequency. For instance measuring 10 KHz with a PD10 Sensor and Nova II where the maximum frequency for every pulse on the Nova II is 4 KHz: in this case, the Nova II will pick out pulses at a rate of close to 4 KHz and sample them, i.e. the Nova II will record 40% of the pulses.
- I have multiple sensors. Do I need a specific meter for each sensor or can I use one meter for all of my sensors?答案
With Ophir's Smart Head technology sensors can be interchanged between different meters easily. The calibration and setting information is stored in the sensors Smart Head connector so it moves with the sensor to the new meter. It is recommended that you power off your Nova meter before removing the sensor, but the new Nova II and Vega meters detect that a sensor has been removed or attached and will power cycle themselves when doing this.
- What is the Ophir meter zeroing and how often should I zero my power meter?答案
In all Ophir instruments, all adjustments, including zeroing internal circuits, are done from the software. This ensures simple and accurate realignment. The zeroing process helps eliminate internal biases in the unit which could affect accuracy and repeatability of measurements. It is recommended to re-zero the instrument every month or two for best performance. Specific instructions for doing this can be found in the User Guide/Manual for each instrument.
- Can I use a third party sensor with the Ophir power/energy meters?答案
No, only Ophir power/energy sensors with the Smart Head connection will work with the Ophir power/energy meters.
- Do I need to recalibrate my instrument? How often must it be recalibrated?答案
Unless otherwise indicated, Ophir sensors and meters should be recalibrated within 18 months after initial purchase, and then once a year after that.
- Why wasn’t the firmware upgraded to the latest version when the meter was sent in for recalibration?答案
Our recalibration process is to not automatically upgrade the firmware in meters when they are sent in for recalibration, unless specifically requested to upgrade it. The reason for this is that we support many companies, such as medical companies, that have equipment validation processes that don’t allow changing the firmware version from the currently validated version. If you do want the latest firmware version installed, we will do that at no additional charge (for meters which are upgraded electronically) if it is specifically requested on the RMA request checklist form. For older meters (such as the Nova) that are upgraded through changing the EEPROM, a nominal fee is added, if firmware upgrade is requested. Note that upgrading the firmware does not affect the calibration.
- Can I buy a universal power adapter/charger for my Ophir display?答案
Yes. We now offer a switchable universal power adapter/charger P/N
for the Ophir displays. - My meter seems to be charging normally, but it lasts for less than an hour on battery power. Does the battery need to be replaced?答案
Yes, the battery needs to be replaced. A new battery should last 8 hours per charge. We recommend that you send the meter back for battery replacement and recalibration. User battery replacement is possible. For battery part numbers and ordering information, check out the Spare Parts.
- What is Ophir Statement of Volatility of Memory for Nova?
答案
配件
Carrying Case
Carrying case 38x30x11 cm. For laser power / energy meter and up to three sensors
Cables
Battery Pack for Nova
Replacement battery pack for Nova
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | 7E14005ABattery Pack for NovaSpare Battery Pack, Nova Power Meter | 有库存 |
Nova PE-C Adapter
The adapter plugs between the Nova D15 socket and the smart plug of the PE-C and PD-C sensors to allow the Nova to operate with these sensors.
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | 7Z08272Energy Sensor Adapter, Connect PE-C and PD-C to Nova Meter | 有库存 |
N Polarity Power Supply/Charger
Power Supply/Charger for Centauri, Vega, Nova II, LaserStar, Nova, EA-1, Pulsar, Quasar, 6K-W, 120K-W, 150K-W and fan cooled sensors.
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | 7E05029N Polarity Power Supply/ChargerDC Power Supply / Charger, N Polarity | 有库存 |
Nova Screen Protector
General Purpose I/O Connector
Used as analog output plug for Centauri, StarBright, StarLite, Vega, Nova II, Nova, and Juno+.
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | 7E02008Analog Output Connector, Power and Energy MetersAnalog Output Connector, Power and Energy Meters | 有库存 |
Extended Warranty for Sensor
Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | XWAR-SENSORExtended Warranty for Sensor |
资源
Data Sheets
Nova Datasheet(200.7 kB, PDF)
Drawings & CAD
Nova Drawing(183 kB, PDF)
Manuals
Nova User Manual(1.1 MB, PDF) Nova Quick Reference(51.7 kB, PDF)
Selection Guides
Meter Comparison Chart(103.2 kB, PDF)
Catalogs
Power/Energy Meter Catalog(25.5 MB, PDF) Laser Power & Energy Measurement and Laser Beam Analysis Catalog(27.5 MB, PDF) Power Meters Catalog(6.5 MB, PDF)
Technical Articles
Main Memory Volatility Statement for Nova Meter(205.4 kB, PDF) The Use of Ophir Instrumentation in Law Enforcement Ophir Power/Energy Meter Calibration Procedure and Traceability/Error Analysis Laser Measurements in Materials Processing Power and Energy Meters: From Sensors to PC
Technical Notes
5 Situations Where Laser Performance Measurement is Necessary How do I know what range, or scale, to set my power/energy meter to?
Software