Juno is a compact Laser Power/Energy Meter virtual meter
Allowing connectivity of Ophir’s smart (DB-15) power and energy sensors to computers (PC, laptops and others) using USB connectivity. It allows remote monitoring and control of the meter via customer custom software, or the Ophir provided PC application.
- 虚拟激光功率计 - 从传感器到PC接口 - 无需电源供应
- 所有标准 Ophir 智能传感器都可以即插即用
- 与StarViewer安卓免费应用程序配合使用,将您的智能手机/平板电脑变为一台功率计
- 记录每个能量脉冲,最高达10KHz
- 通过包含的StarLab应用程序记录功率和能量、平均值、统计数据、柱状统计图及许多其它项目
- 包含系统集成商工具:LabVIEW VI、COM对象接口 查看所有功能
Software
PC Software & Drivers
This section describes various ways to interface the Ophir meter to your PC as well as the software options available. Check out the datasheet for more details.
The StarLab application together with an Ophir meter turns your PC or laptop into a full-fledged laser power/energy meter. Supports most Ophir laser power/energy sensors. Up to 8 sensors can be displayed at once on one PC. By using the Ophir COM Object, you can control the device from your own application. Supports the Ariel, Centauri, StarBright, StarLite, Juno, Juno+, Juno-RS, Nova II, Vega, Pulsar-1/2/4, Quasar, EA-1 and Ariel devices.
Library supplied for a complete measurement interface with most of our USB speaking devices (Centauri, StarBright, StarLite, Juno, Juno+, Nova-II, Pulsar, Vega). Makes use of our new COM object.
StarViewer turns your Android or iOS based smartphone into a portable Ophir laser power / energy measurement monitor.
The iOS version of StarViewer works with Ariel sensor.
The Android version of StarViewer works with Ariel, as well as with Juno and Quasar interfaces.
Firmware - Juno (latest version 1.53)
Embedded Software for Juno Interface
Use StarLab to upgrade the firmware of your device. Follow the step-by-step instructions (see link above).
规格
- 产品名称Juno
- 热传感器兼容性Yes
- 光电二极管传感器兼容性Yes
- 热释电传感器兼容性Yes
- 光束跟踪传感器的兼容性Yes
- 统计Yes
- 模拟输出No
- 触发输入/输出No
- 电源USB bus powered
- USBYes
- 数据传输率10,000 Hz
- 板载数据存储No
- 自动化接口Yes
- Labview VI'sYes
- CE 符合性Yes
- UKCA 符合性Yes
- 中国 RoHS 符合性Yes
功能
Laser Measurement PC Interfaces
If all your laser measurement work involves a laptop or a PC, rather than a stand-alone meter, one of Ophir's direct-to-PC interfaces could be an ideal solution. These are full-fledged Laser Power and Energy meters, but instead of having a separate on-board display, the PC becomes your display. In this video you will learn about the range of PC Interfaces available from Ophir.
Introduction to the StarLab Laser Measurement Application
This video gives an overview of the StarLab application and its various functions. Part 1 of a series of video segments teaching you how to use StarLab.
StarLab 3.0: Introduction and First Steps
This video explains the various items on the StarLab screen, and shows you how to perform basic laser measurements. Part 1 of a series of video segments teaching you how to use StarLab.
StarLab 3.0: Second Steps
Sometimes we want to not only get a reading, but perform additional processing on the reading. This video shows you how to use various functions in StarLab, such as Averaging, Scale Factor, Normalize, Density, etc. Part 2 of a series of video segments teaching you how to use StarLab.
Ophir Laser Measurement Virtual Meters
If all your laser measurement work involves a laptop or a PC, one of Ophir's direct-to-PC virtual meters could be an ideal solution. These are full-fledged Laser Power and Energy meters, and - together with the sensor and Ophir’s powerful StarLab software application - turn your PC into a full-function, multi-channel laser measurement workstation.
In this webinar, you will learn about the range of virtual meters and interface options available from Ophir.
常见问题
- What is the maximum number of sensors that can be connected via USB to one PC?答案
In theory USB supports up to 127 devices.
We recently had 12 sensors connected to StarLab, and it worked normally. The practical limitation is basically how many channels you can realistically see on the display (which would not be a limitation if you will only be logging the data), and of course the number of available USB ports/hubs. - How can I control Ophir USB speaking devices from the PC?答案
All USB speaking devices (EA-1, Juno, Juno+, Pulsar and USBI as well as the StarBright, Centauri, Vega, Nova-II, and StarLite Power and Energy Meters) can be controlled via our StarLab. This provides full remote control and measurement capabilities. In addition, system integrators can make use of the OphirLMMeasurement COM object for all of our USB speaking devices that are included in the application installation. Documentation and Examples in Visual Basic, LabVIEW are found in the "Automation Examples" sub-directory of your StarLab directory.
- 题答案
回答
- How can I interface my Ophir Power Meter (Juno, Pulsar, NOVA II, Vega) to LabVIEW?答案
For customers using the new LabVIEW COM Demo, there is nothing additional to do. Just open it and get started. If writing your own LabVIEW application, make sure that the OphirLMMeasurement COM Object is included in your LabVIEW application.
For customers using the legacy OphInstr LabVIEW package, here are additional clarification steps to assist establishing the interface to LabVIEW when connecting an Ophir meter such as the Juno/USBI/Nova II/Vega with the USB.
The sequence for preparing to interface the Ophir Juno (or meters connected through USB) with LabVIEW is generally as follows:
- Disconnect any Juno OPHIR Device from the PC
- Run SwapINF utility
- Set LabVIEW option On
- Press "Swap" button - You will be prompted to "Remove the Ophir Juno Devices before continuing"
- Press "OK" (you have already removed these)
- Press "OK" again (after SwapINF is done)
- Reconnect the Ophir Juno device to the PC that you wish to apply LabVIEW VI's on If asked by Wizard (i.e. in XP) to update software etc.
- Select "not this time" & press "next" button
- Again, press "next" (install software automatically)
From here on you may apply LabVIEW VI's on your device.
- I see there is newer version of StarLab software available. Why should I upgrade?答案
Ophir periodically releases new versions of StarLab, adding new features and fixing bugs, so it's a good idea to keep updated with the latest StarLab version.
- Logging data from multiple sensors: How “in synch” are the time stamps?答案
Sometimes an application requires logging power from multiple power sensors, and being able to compare readings from the different sensors. In such cases, it is necessary to know to what degree the time points of each “channel” are in synch with each other.
Possible solutions would be to use a 2-channel Pulsar, or for example 2 Juno/Juno+.
With Ophir power sensors, the logged data timestamps originate from the PC, with millisecond resolution, for both Pulsar’s and Juno/Juno+.
So basically there is no difference between a Pulsar and a Juno/Juno+ in that respect. They will perform the same.
Each measurement will have its own separate timestamp, and will not have the exact same zero point. However, they will be ‘synced’ to each other to within a millisecond or so. Keep in mind that with power measurements, the instrument’s A/D sampling rate of the power signal is 15 Hz (i.e. every 66.67 msec), so for all practical purposes the 2 channels can be considered in synch with each other.
- Do I need to recalibrate my instrument? How often must it be recalibrated?答案
Unless otherwise indicated, Ophir sensors and meters should be recalibrated within 18 months after initial purchase, and then once a year after that.
- What is Ophir Statement of Volatility of Memory for Juno?
答案
配件
USB MINI-B Cable
Cable USB2.0 A MINI-B (1 unit supplied with the product).
Extended Warranty for Sensor
Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.
| 对比 | 型号 | 图纸、CAD和参数 | 库存 | 价格 | ||
|---|---|---|---|---|---|---|
![]() | XWAR-SENSORExtended Warranty for Sensor |
资源
Data Sheets
Juno Datasheet(824.7 kB, PDF)
Drawings & CAD
Juno Drawing(216.1 kB, PDF)
Manuals
StarLab User Manual(5.5 MB, PDF)
Technical Notes
StarViewer User Note(711 kB, PDF) 5 Situations Where Laser Performance Measurement is Necessary How do I know what range, or scale, to set my power/energy meter to? When you log energy from multiple sensors in parallel using StarLab Installing LabVIEW support for Ophir Power Meters and PC Interfaces Longer Length Sensor Cables Power Meter System Integration
Catalogs
PC Interface Meter Brochure(562.3 kB, PDF) Power/Energy Meter Catalog(25.5 MB, PDF) Laser Power & Energy Measurement and Laser Beam Analysis Catalog(27.5 MB, PDF) Power Meters Catalog(6.5 MB, PDF)
Technical Articles
Main Memory Volatility Statement for Juno Meter(204.8 kB, PDF) Low Frequency Power Mode Ophir Power/Energy Meter Calibration Procedure and Traceability/Error Analysis Laser Measurements in Materials Processing Power and Energy Meters: From Sensors to PC
Software
StarLab.zip(119 MB, ZIP) Juno Firmware Version 1.53(216 kB, BIN) Juno Firmware Version 1.53(216 kB, BIN)