StarBright
- Compatible with all standard Ophir thermal, BeamTrack, pyroelectric (PE-C series) and photodiode sensors
- Brilliant color large size TFT 320x240 display
- Choose between Digital with Bargraph, Analog Needle, Line Plot (for laser tuning), Pulse Chart, Pass/Fail, Position, Stability, Real Time Statistics displays
- Sophisticated power and energy logging, including logging every point at up to 5000Hz with Pyro sensors
- Math functions for advanced processing such as Density, Scale Factor, Normalize against base line, etc.
- Can mix functions together and display the results graphically. Function results can also be logged.
- USB Disk on Key (Thumb Drive) for nearly unlimited data storage.
- USB and RS232 interfaces with StarLab PC applications and User Commands document
- LabVIEW driver and COM Object Interface
- Pulsed Power measurements with Thermopile sensors
- Exposure measurement (Energy Summing) with Photodiode sensors
- New: Low Frequency Power on Photodiode sensors - power measurement based on pulse cycle (for VCSEL)
- Select between English, Japanese, Russian, and Chinese interfaces
- Soft keys and menu driven functions with context sensitive help
- Compact handheld design with rubberized bumpers and optimized kickstand
- Backlighting and rechargeable battery
- Scalable Analog Output
Specification
- Yes
- Yes
- Yes
- Yes
- Yes
- 1V,2V,5V,10V
- RS232, USB
- No
- N/A
- 15Hz
- N/A
- 5000Hz
- N/A
- As per USB Flash Drive used
- Yes for USB
- Yes
- CE, UKCA, China RoHS
Catalog & Manuals
FAQ
I don't see my exact wavelength in the wavelength option for my Ophir sensor. I only see several wavelength ranges. What should I do?
Select the range that contains your wavelength. The sensors have coatings on them that have been characterized and for any wavelength within that range the sensor will be within calibration tolderance including variations in sensitivity within that range. When there is a difference in sensitivity that exceeds the allowable tolerances, a new wavelength range is created and a calibrated for.
CloseI can understand why a power meter sensor needs to be recalibrated, but why do I have to have my Power and Energy Meters recalibrated?
Think of it like a voltmeter or ammeter, these have to be recertified/recalibrated as well like most other pieces of test equipment. In general, our instruments are unlikely to drift or fail over time like a sensor might that is constantly exposed to laser energy. But the possibility exists. So the general practice in our industry is to have Power and Energy Meterss recalibrated and recertified as well. ISO standards and FDA, as well as other agencies, require both be recalibrated and recertified.
CloseWhat is the Ophir meter zeroing and when should it be performed?
In all Ophir instruments, all adjustments, including zeroing internal circuits, are done from the software. This ensures simple and accurate realignment. The zeroing process helps eliminate internal biases in the unit which could affect accuracy of measurements. It is recommended to re-zero the instrument every 2 months for best performance. Specific instructions for doing this are found in the relevant User Manual for each instrument.
CloseI’ve upgraded to the latest version of StarLab and my meter no longer is supported. What happened?
Whenever we release a new version of StarLab we add support or deal with various other meter-specific issues. This may necessitate upgrading the meter firmware to the latest release. This release is included in the StarLab package and simply enter the Field Upgrade dialog in order to upgrade your meter to be up to date.
CloseDo I need to recalibrate my instrument? How often must it be recalibrated?
How do I use the Analog Output of a meter to get a reading of power? And how accurate is it?
The analog output of the meter - using the mating connector provided – gives a voltage signal proportional to the actual reading (it is in fact just a D/A translation of what is being displayed), so it represents a fully calibrated reading. The full scale value is a function of the meter being used and the power range it is on. With the StarBright, Vega and Nova II, for example, the user can select full scale analog output voltage ranges of 1v, 2v, 5v or 10v, and the 100% level of the chosen power scale is scaled to the full scale voltage. For example: if you choose 5V full scale analog voltage range, and your sensor is set to a 50W full scale power range, then you will have 5V = 50W or 0.1 V/W. It will vary according to the chosen power range and chosen full scale voltage range. The electrical accuracy is stated in the specification (see the User manual) as ±0.2% (of reading) ±0.3% of full scale volts (in addition to the calibration accuracy of the sensor’s reading itself).
CloseWhat is Ophir Statement of Volatility of Memory for StarLite StarBright
Will the StarBright and StarLite meters work with old pyroelectic sensors that are not the C style?
How often should I zero my power meter?
For the best accuracy and repeatability, each Ophir meter should be zeroed with no sensor connected periodically. It would not hurt to zero the meter each time it is used, but we recommend to zero the meter at least once a month. See your meter User Guide for the zeroing procedure particular to your meter. To view or download a copy of the meter User Guides, follow this link: https://www.ophiropt.com/laser-measurement-instruments/laser-power-energy-meters/services/manuals.
Close
Why wasn’t the firmware upgraded to the latest version when the meter was sent in for recalibration?
Our recalibration process is to not automatically upgrade the firmware in meters when they are sent in for recalibration, unless specifically requested to upgrade it. The reason for this is that we support many companies, such as medical companies, that have equipment validation processes that don’t allow changing the firmware version from the currently validated version. If you do want the latest firmware version installed, we will do that at no additional charge (for meters which are upgraded electronically) if it is specifically requested on the RMA request checklist form. For older meters (such as the Nova) that are upgraded through changing the EEPROM, a nominal fee is added, if firmware upgrade is requested. Note; upgrading the firmware does not affect the calibration.
CloseCan I buy a universal power adapter/charger for my Ophir display?
My meter seems to be charging normally, but it lasts for less than an hour on battery power. Does the battery need to be replaced?
Yes, the battery needs to be replaced. A new battery should last 8 hours per charge. We recommend that you send the meter back for battery replacement and recalibration. User battery replacement is possible. For battery part numbers and ordering information, go to https://www.ophiropt.com/laser--measurement/spare-parts.
ClosePC Software & Drivers
This section describes various ways to interface the Ophir meter to your PC as well as the software options available.
StarLab
The StarLab application together with an Ophir meter turns your PC or laptop into a full-fledged laser power/energy meter. Supports most Ophir laser power/energy sensors. Up to 8 sensors can be displayed at once on one PC. By using the Ophir COM Object, you can control the device from your own application. Supports the Ariel, Centauri, StarBright, StarLite, Juno, Juno+, Juno-RS, Nova II, Vega, Pulsar-1/2/4, Quasar, EA-1 and IPM sensor devices.
LabVIEW
Library supplied for a complete measurement interface with most of our USB speaking devices (Centauri, StarBright, StarLite, Juno, Juno+, Nova-II, Pulsar, Vega). Makes use of our new COM object.
Firmware - StarBright
Embedded s/w for StarBright Laser Power / Energy Meter
Latest StarBright firmware (version 1.50)
Notes: Firmware update is performed by downloading the installer from Ophir website (see link above).
The firmware can't be updated via StarLab.
System Integrators
Besides their use as stand-alone, fully featured laser power/energy meters, Ophir devices are easily incorporated into larger end-user applications. This allows system integrators to leverage Ophir’s excellence in measurement capabilities with legacy analysis packages.
RS232
RS232 communication is the simplest to integrate into your OEM application. Integrated Development Environments (IDE’s) such as Microsoft Visual Studio provide functions and methods for accessing the PC’s com port.
The following is all that you need to get your RS232 applications up and running
- User Commands contains an alphabetical listing and detailed description of all commands available with the Juno, Juno+, Juno-RS, Pulsar, Centauri, Nova-II, Vega, StarLite, and StarBright devices.
- StarBright RS232 cable (P/N 7E01213). Included with the StarBright.
USB
Ophir provides a common interface for communication and control of all of our USB speaking devices. OphirLMMeasurement is a COM Object that is included as part of the StarLab installation (StarLab 2.10 and higher) that allows the system integrator to take control of the Juno, Juno+, Nova-II, Pulsar, Vega, Centauri, StarBright and StarLite devices; integrating them into his in-house measurement and analysis package.
System Integrators will need the following components:
- OphirLMMeasurement COM Object.pdf lists and describes the methods and events available for configuring, controlling and uploading measurements from Ophir devices.
- OphirLMMeasurement.dll. COM object component developed and supplied by Ophir for communication with the Juno, Juno+, Nova-II, Pulsar, Vega, Centauri, StarBright and StarLite devices. The COM object is registered when the application is installed.
- OphirLMMeasurement COM Object.pdf describes how to register it on another PC where the Ophir application has not been installed.
- Standard micro-B USB cable (P/N 7E01279) for use with the StarBright device (included).
- Ophir provides example projects of COM Object clients in VC#, VB.NET and LabVIEW. These are found in the Automation Examples subdirectory of our StarLab PC Application.
- For direct control of the device, refer to User Commands.
Videos

The new Ophir StarBright is the most advanced of Ophir’s family of handheld laser power meters. This video was also separated into 12 short segments that can be found here. Each segment walks you through one of StarBright's capabilities, and shows you how to use it.

For measuring high average powers, you need to use a high average power sensor (read: big, heavy, water-cooled, expensive). Right?
Well, partly right.
There are ways to “get away” with using lower power sensors to measure high power beams, using short exposure times. This video shows you 3 practical solutions.

When a power/energy meter is in "Calibrate" mode, various "Factors" are displayed to the user. This video explains the meaning of each of these factors.
Field upgrade of the firmware for the StarLite and StarBright meters is very simple. In this video, we’ll walk through the process, step by step
Tutorials
Ophir Power/Energy Meter Calibration Procedure and Traceability/Error Analysis
This document discusses the interpretation and basis for stated measurement accuracy of Ophir Laser Power/Energy meters.
1. General Discussion
2. Combination of Errors and Total Error
3. Analysis of Power and Energy Calibration Errors
4. Detailed Analysis of Power and Energy Calibration Errors
Laser Measurements in Materials Processing: How and When They Absolutely, Positively Must Be Made
How do I know what range, or scale, to set my power/energy meter to? And what happens if I go over range?
Each given range represents one level of gain of an internal amplifier. The electronics, as always, have a limited Dynamic Range. If the measured signal is too low, in other words near the bottom of the range, then it may be lost in the noise and the reading will be inaccurate and noisy. If it’s too high – there may be saturation issues. To give an instrument a usefully wide dynamic range, multiple scales or ranges are used. Switching from range to range can be automatic (“Autorange”), or manual. Autoranging simply starts automatically at the least sensitive range and works its way down the ranges, sampling the signal as it goes, till it finds a range at which the signal is properly detected. Note, by the way, that only in POWER mode is Autoranging available. If we are working in Single Shot Energy mode, there is no Autoranging – simply because when we are measuring a single pulse, the instrument has no opportunity to work its way down the ranges as in Power mode.
 Read more...White Paper – Low Frequency Power Mode
Pulse Power Measurement: Measuring Instantaneous Power of a Short Pulse
5 Situations Where Laser Performance Measurement is Necessary
Power and Energy Meters: From Sensors to PC
Specification
- Yes
- Yes
- Yes
- Yes
- Yes
- 1V,2V,5V,10V
- RS232, USB
- No
- N/A
- 15Hz
- N/A
- 5000Hz
- N/A
- As per USB Flash Drive used
- Yes for USB
- Yes
- CE, UKCA, China RoHS
PC Software & Drivers
This section describes various ways to interface the Ophir meter to your PC as well as the software options available.
StarLab
The StarLab application together with an Ophir meter turns your PC or laptop into a full-fledged laser power/energy meter. Supports most Ophir laser power/energy sensors. Up to 8 sensors can be displayed at once on one PC. By using the Ophir COM Object, you can control the device from your own application. Supports the Ariel, Centauri, StarBright, StarLite, Juno, Juno+, Juno-RS, Nova II, Vega, Pulsar-1/2/4, Quasar, EA-1 and IPM sensor devices.
LabVIEW
Library supplied for a complete measurement interface with most of our USB speaking devices (Centauri, StarBright, StarLite, Juno, Juno+, Nova-II, Pulsar, Vega). Makes use of our new COM object.
Firmware - StarBright
Embedded s/w for StarBright Laser Power / Energy Meter
Latest StarBright firmware (version 1.50)
Notes: Firmware update is performed by downloading the installer from Ophir website (see link above).
The firmware can't be updated via StarLab.
Accessories
-
Carrying Case
1J02079Carrying case 38x30x11cm. For laser power / energy meter and up to three sensors
-
USB-A to MICRO-B cable (1 unit supplied with StarLite, StarBright & Centauri)
-
StarBright/Centauri RS232 Cable
7E01213D9 to 3.5mm plug cable (1 unit supplied with StarBright & Centauri)
-
StarBright / StarLite Battery Pack
7E14008Replacement battery pack for StarBright & StarLite
-
P Polarity Power Supply/Charger
7E05047Power Supply/Charger for StarLite, StarBright and RM9 Chopper (1 unit supplied with these products)
-
StarBrigh Screen Protector
12255-005StarBrigh Screen Protector
-
General Purpose I/O Connector
7E02008Used as analog output plug for Centauri, StarBright, StarLite, Vega, Nova II, Nova, and Juno+ (1 unit supplied with these products).
For Centauri Only – 2 additional units are supplied to be used for external trigger and TTL output. -
Extended Warranty for Power Meter
XWAR-METEROphir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration. More info