Jump to navigation

Home
  • Products
    • Power & Energy Measurement
      • Laser Power Sensors
        • Laser Photodiode Sensors
        • Laser Thermal Power Sensors
        • Optical Power Meters for Telecom
        • High Speed, Multifunctional Integrating Spheres for VCSEL
        • Terahertz Laser Measurement
      • Laser Energy Sensors
        • Photodiode Energy Sensors
        • Laser Pyroelectric Energy Sensors
        • Energy Sensors for IPL Sources
        • Sensor Finder
        • Meter Finder
      • Industrial Power Meter System
      • Pulse Characterization Sensors
      • OEM Products
      • Power / Position / Size Sensors
      • High Power Measurement from Short Exposure
      • Divergent Light Measurement
      • Beam Dumps & Beam Traps
      • Spare Parts
      • Power / Energy Meters
        • Centauri Dual Channel
        • Centauri Single Channel
        • StarBright
        • Vega
        • Nova II
        • StarLite
        • LaserStar Dual Channel
      • PC Interfaces
        • Compact USB - Juno
        • USB - Juno+
        • RS232 - Juno-RS
        • Ethernet - EA-1
        • Multi-Channel - Pulsar 1/2/4
        • Bluetooth - Quasar
    • Laser Beam Analysis
      • Beam Profiling for 266nm to 3000μm
        • BeamGage - Camera Based
        • BeamMic For Entry Level - Camera Based
        • NanoScan - Slit Based
      • High-Power Beam Profiling
        • BeamWatch® For 980-1080 nm
        • BeamWatch® Integrated
        • BeamPeek™
        • BeamWatch® AM for Additive Manufacturing
        • BeamCheck™ For Additive Manufacturing
      • Measure Focus Spot
        • Focal Spot Analyzer for 266nm to 1100nm
        • BeamWatch For 980-1080 nm
      • M² – Beam Propagation Analysis
        • BeamSquared® Camera Based
        • NanoModeScan Slit Based
        • Integrated Solutions
      • Beam Profiler Finder
      • Beam Profiling Accessories
        • Optical Camera Trigger
        • Neutral Density Filters
        • Beam Splitters
        • Neutral Density + Beam Splitter Combo
        • Beam Expanders + Microscope Objectives
        • Beam Reducers
        • Wide Beam Imager
        • Lenses for Front End Imaging
        • Reimaging Products for UV Lasers
        • Near Field Profilers
    • LED Measurement
      • Power Measurement
        • Calibrated Integrating Sphere
        • PC Interfaces
        • Meters
      • Irradiance & Dosage
  • Solutions
    • Applications
      • Customized Solutions
      • Eye Safety
      • Fiber Optics
      • LED Measurements
      • THz Measurement
      • UVA
      • VCSEL
    • Industries
      • Additive Manufacturing
      • Automotive
      • Directed Energy
      • IPL
      • Materials Processing
      • Micro Processing
      • Medical
      • Scientific
      • Telecom
  • Calibration
    • Request RMA
    • Calibration Centers
    • Calibration Portal (US only)
    • ISO Accreditation
    • ISO/IEC 17025
    • MKS Global Service
  • Support
    • Request RMA
    • Product Search Tools
      • Sensor finder
      • Meter finder
      • Measurement Modes Available
      • Beam Profiler Finder
      • Profiler Selection Chart
      • Download Sensor Finder
      • Discontinued Products
    • Knowledge Center
      • Search
      • Videos
      • Articles
      • Power & Energy FAQs
      • Beam Profilers FAQs
    • Calculators
      • Power Density Calculator
      • Peak Power Calculator
      • Power Through Aperture Calculator
      • Focal Spot Size Calculator
      • Laser Focusability Calculator
      • Temperature Rise Calculator
      • LED Sensor Finder
      • NanoScan Damage Threshold Calculator
    • Power & Energy Downloads
      • Software Solutions
      • Software / Firmware Listing
      • Catalogs
      • Manuals
    • Beam Profilers Downloads
      • Software
      • Catalogs
      • Manuals
    • Distributors
      • Power Meter Distributors
      • Beam Profilers Distributors
      • Corporate Sites
    • Compliances
      • ISO Accreditation
    • Policies
      • Warranty Policy
      • Perpetual Lifetime Warranty Terms and Conditions
      • Terms of Sale
      • Quality and Environmental Policy
    • Volatility Statements
  • Contact
    • Contact
      • Corporate Sites
      • Power Meters Distributors
      • Beam Profilers Distributors
      • Calibration Centers
    • About Ophir
      • Ophir Photonics
      • Our Family
      • Compliances
    • Blog
    • News & Events
      • Press Releases
      • New Products
      • Newsletter - ePulse
      • Trade Shows
Home > Laser Thermal Power Sensors > Medium Power Thermal Sensors – 100mW to 300W

Medium Power Thermal Sensors – 100mW to 300W

More videos are available on our video page

Apertures from 50 to 65 mm. Sensors for larger beams and higher powers. Compact sensors for intermittent use.

Download catalog Sensor finder Contact us
Click here to find the right sensorX
  •  
    L40(250)A-BB-50 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L40(250)A-BB-50

    7Z07110
    • Ø50mm
    • 0.19-11µm
    • 300mW-250W
    • 100mJ-4000J
    • 90 L x 90 W x 33 D (mm)
    The L40(250)A-BB-50 is a general purpose thermal power/energy laser measurement sensor with a 50mm aperture. It can measure from 300mW to 35W continuously and to 250W intermittently. It can measure energy from 100mJ to 4000J. It has the spectrally flat broadband coating and covers the spectral range from 0.19 to 11µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L40(250)A-LP2-50 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L40(250)A-LP2-50

    7Z02794
    • Ø50mm
    • 0.25-2.2µm, 2.94 µm
    • 300mW-250W
    • 100mJ-10,000J
    • 90 L x 90 W x 33 D (mm)
    The L40(250)A-LP2-50 is a thermal power/energy laser measurement sensor for high power density and long pulse lasers. It has a 50mm aperture and can measure from 300mW to 40W continuously and to 250W intermittently. It can measure energy from 100mJ to 10,000J. The sensor is able to measure high power lasers of up to 10kW by measuring the energy of 0.3 - 2s exposure to the laser. The high damage threshold LP2 absorber covers the spectral range from 0.25 to 2.2µm and 2.94µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L40(500)A-LP2-DIF-35 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L40(500)A-LP2-DIF-35

    7Z02797
    • Ø35mm
    • 0.44-2.2µm
    • 300mW-500W
    • 100mJ-2,000J
    • 90 L x 90 W x 45 D (mm)
    The L40(500)A-LP2-DIF-35 is a thermal power/energy laser measurement sensor for high power density and very small diameters lasers. It has a 35mm aperture and can measure from 300mW to 40W continuously and to 500W intermittently. It can measure energy from 100mJ to 2,000J. The sensor is able to measure high power lasers of up to 4kW with a 3.5mm diameter beams by measuring the energy of 0.4 - 4s exposure to the laser. The high damage threshold LP2 absorber together with the diffuser cover the spectral range from 0.44 to 2.2µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L40(200)A-EX-50 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L40(200)A-EX-50

    7Z02795
    • Ø50mm
    • 0.15-0.7µm, 10.6µm
    • 300mW-200W
    • 100mJ-200J
    • 90 L x 90 W x 33 D (mm)
    The L40(200)A-EX-50 is a thermal power/energy laser measurement sensor for use with excimer lasers. It has a 50mm aperture and can measure from 300mW to 35W continuously and to 200W intermittently. It can measure energy from 100mJ to 200J. Its EX absorber has a damage threshold of 0.5J/cm² and covers the spectral range from 0.15 - 0.7um and 10.6µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L40(150)A-IPL| Laser Thermal Power Sensors | Power Sensors - Ophir

    L40(150)A-IPL

    7Z02771
    • 22x22mm
    • 0.5-1.3µm
    • N.A.
    • 100mJ-2,000J
    • 90 L x 90 W x 62 D (mm)
    L40(150)A-IPL sensor for gel measurements. This sensor is specially designed for measuring pulses from gel coupled IPL dermatological sources. It allows a widely divergent gel coupled beam to go through the unit without back reflections. The sensor has a 22x22mm aperture that can also sample larger sized sources and can measure energy from 100mJ to 2000J. It has the high damage threshold LP2 absorber and covers the spectral range from 0.5 to 1.3µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L50(250)A-BB-50 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L50(250)A-BB-50

    7Z07109
    • Ø50mm
    • 0.19-11µm
    • 300mW-250W
    • 100mJ-4000J
    • 100 L x 100 W x 39 D (mm)
    The L50(250)A-BB-50 is a general purpose thermal power/energy laser measurement sensor with a 50mm aperture. It can measure from 300mW to 50W continuously and to 250W intermittently. It can measure energy from 100mJ to 4000J. It has the spectrally flat broadband coating and covers the spectral range from 0.19 to 11µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L50(300)A | Laser Thermal Power Sensors | Power Sensors - Ophir

    L50(300)A-BB-65

    7Z07127
    • Ø65mm
    • 0.19-11µm
    • 400mW-300W
    • 200mJ-300J
    • 120 L x 120 W x 30 D (mm)
    The L50(300)A-BB-65 is a general purpose thermal power/energy laser measurement sensor with a 65mm aperture. It can measure from 400mW to 50W continuously and to 300W intermittently. It can measure energy from 200mJ to 300J. It has the spectrally flat broadband coating and covers the spectral range from 0.19 to 11µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L50(300)A-LP2-65  | Laser Thermal Power Sensors | Power Sensors - Ophir

    L50(300)A-LP2-65

    7Z02782
    • Ø65mm
    • 0.25-2.2µm
    • 400mW-300W
    • 200mJ - 1000J
    • 120 L x 120 W x 30 D (mm)
    The L50(300)A-LP2-65 is a thermal power/energy laser measurement sensor for high power density and long pulse lasers. This sensor also measures air coupled pulses from IPL dermatological sources. It is similar to the L50(300)A-IPL but does not have the window so is for air coupled sources only. It gives the most accurate measurements for air coupled sources. It has a 65mm aperture and can measure from 400mW to 50W continuously and to 300W intermittently. The sensor can measure energy from 200mJ to 1000J. Its high damage threshold LP2 absorber covers the spectral range from 0.25 to 2.2µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L50(300)A-PF-65 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L50(300)A-PF-65

    7Z02743
    • Ø65mm
    • 0.15-20µm
    • 400mW-300W
    • 200mJ-300J
    • 120 L x 120 W x 30 D (mm)
    The L50(300)A-PF-65 is a thermal power/energy laser measurement sensor for high peak power pulsed lasers. It has a 65mm aperture and can measure from 400mW to 300W intermittently and to 50W continuously. It measures energy from 200mJ to 300J. It has a damage threshold of up to 3J/cm² for ns pulses and covers the spectral range from 0.15 to 20µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L50(300)A-IPL| Laser Thermal Power Sensors | Power Sensors - Ophir

    L50(300)A-IPL

    7Z02780
    • Ø65mm
    • 0.5-1.3µm
    • 400mW-300W
    • 120mJ-1,000J
    • 120 L x 120 W x 30 D (mm)
    L50(300)A-IPL sensor for air or gel measurements. This sensor measures pulses from IPL dermatological sources. It has a 65mm aperture with a glass window allowing measurement thru air or using gel. It can measure energy from 120mJ to 1000J. It has the high damage threshold LP2 absorber and covers the spectral range from 0.5 to 1.3µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    L100(500)A-PF-120 | Laser Thermal Power Sensors | Power Sensors - Ophir

    L100(500)A-PF-120

    7Z02765
    • Ø120mm
    • 0.15-20µm
    • 1W-500W
    • 6J-6000J
    • Ø200 W x 35 D (mm)
    The L100(500)A-PF-120 is a convection or conduction cooled thermal power/energy laser measurement sensor with the very large aperture of 120mm. It can measure power from 1W to 500W and energy from 6J to 6000J. It has the PF volume absorber and covers the spectral range from 0.15 to 20µm. The sensor comes with a standard 1.5 meter cable for connecting to a meter or PC interface.
    More info

Contact Us

How can we help you?

Send us your information and we will assist you as quickly as we can.

(* Indicates required field)

Laser Power & Energy measurement

Laser Beam Profiling

LED Measurement

Sensor Finder

Meter Finder

Solutions

Beam Profiler Finder

Power Meter Software Solutions

Profiler Selection Chart

Beam Profiling Software

Repair and Recalibration - RMA

Knowledge Center

Calculators

Power Meter Catalog Download

Beam Profiling Catalog Download

Power Meters Distributors

Beam Profiler Distributors

Calibration Centers

  • Contact Us
  • Terms and Conditions
  • Laser calibration
  • Privacy
  • Site Map
  • Newport
  • Ophir Optronics
Copyright © 2023 Ophir Optronics Solutions Ltd