Jump to navigation

Home
  • Products
    • Power & Energy Measurement
      • Laser Power Sensors
        • Laser Photodiode Sensors
        • Laser Thermal Power Sensors
        • Optical Power Meters for Telecom
        • High Speed, Multifunctional Integrating Spheres for VCSEL
        • Terahertz Laser Measurement
      • Laser Energy Sensors
        • Photodiode Energy Sensors
        • Laser Pyroelectric Energy Sensors
        • Energy Sensors for IPL Sources
        • Sensor Finder
        • Meter Finder
      • Pulse Characterization Sensors
      • OEM Products
      • Power / Position / Size Sensors
      • High Power Measurement from Short Exposure
      • Divergent Light Measurement
      • Beam Dumps & Beam Traps
      • Spare Parts
      • Power / Energy Meters
        • Centauri Dual Channel
        • Centauri Single Channel
        • StarBright
        • Vega
        • Nova II
        • StarLite
        • LaserStar Dual Channel
      • PC Interfaces
        • Compact USB - Juno
        • USB - Juno+
        • Ethernet - EA-1
        • Multi-Channel - Pulsar 1/2/4
        • Bluetooth - Quasar
    • Laser Beam Analysis
      • Beam Profiling for 266nm to 3000μm
        • BeamGage - Camera Based
        • BeamMic For Entry Level - Camera Based
        • NanoScan - Slit Based
      • High-Power Beam Profiling
        • BeamWatch® For 980-1080 nm
        • BeamWatch® Integrated
        • BeamWatch® AM for Additive Manufacturing
        • BeamCheck™ For Additive Manufacturing
      • Measure Focus Spot
        • Focal Spot Analyzer for 266nm to 1100nm
        • BeamWatch For 980-1080 nm
      • M² – Beam Propagation Analysis
        • BeamSquared® Camera Based
        • NanoModeScan Slit Based
        • Beam Profiler Finder
        • Integrated Solutions
      • Beam Profiling Accessories
        • Optical Camera Trigger
        • Neutral Density Filters
        • Beam Splitters
        • Neutral Density + Beam Splitter Combo
        • Beam Expanders + Microscope Objectives
        • Beam Reducers
        • Wide Beam Imager
        • Lenses for Front End Imaging
        • Reimaging Products for UV Lasers
        • Near Field Profilers
    • LED Measurement
      • Power Measurement
        • Calibrated Integrating Sphere
        • PC Interfaces
        • Meters
      • Irradiance & Dosage
  • Solutions
    • Applications
      • Customized Solutions
      • Eye Safety
      • Fiber Optics
      • LED Measurements
      • THz Measurement
      • VCSEL
    • Industries
      • Additive Manufacturing
      • Automotive
      • Directed Energy
      • IPL
      • Materials Processing
      • Medical
      • Scientific
      • Telecom
  • Calibration
    • Request RMA
    • Calibration Centers
    • Calibration Portal (US only)
    • ISO Accreditation
    • ISO/IEC 17025
    • MKS Global Service
  • Support
    • Request RMA
    • Product Search Tools
      • Sensor finder
      • Meter finder
      • Measurement Modes Available
      • Beam Profiler Finder
      • Profiler Selection Chart
      • Download Sensor Finder
      • Discontinued Products
    • Knowledge Center
      • Search
      • Videos
      • Articles
      • Power & Energy FAQs
      • Beam Profilers FAQs
    • Calculators
      • Power Density Calculator
      • Peak Power Calculator
      • Power Through Aperture Calculator
      • Focal Spot Size Calculator
      • Laser Focusability Calculator
      • Temperature Rise Calculator
      • LED Sensor Finder
      • NanoScan Damage Threshold Calculator
    • Power & Energy Downloads
      • Software Solutions
      • Software / Firmware Listing
      • Catalogs
      • Manuals
    • Beam Profilers Downloads
      • Software
      • Catalogs
      • Manuals
    • Distributors
      • Power Meter Distributors
      • Beam Profilers Distributors
      • Corporate Sites
    • Compliances
      • ISO Accreditation
    • Policies
      • Warranty Policy
      • Perpetual Lifetime Warranty Terms and Conditions
      • Terms of Sale
      • Quality and Environmental Policy
    • Volatility Statements
  • Contact
    • Contact
      • Corporate Sites
      • Power Meters Distributors
      • Beam Profilers Distributors
      • Calibration Centers
    • About Ophir
      • Ophir Photonics
      • Our Family
      • Compliances
    • Blog
    • News & Events
      • Press Releases
      • New Products
      • Newsletter - ePulse
      • Trade Shows
Home > Laser Thermal Power Sensors > High Sensitivity Thermal Laser Sensors – 300fW to 12W

High Sensitivity Thermal Laser Sensors – 300fW to 12W

More videos are available on our video page

Very low noise and drift optical thermal power meters accurately measure very low laser and LED powers over a wide range of wavelengths from UV to IR. These sensors also measure low single shot laser energies down to tens of µJ.

Download catalog Sensor finder Contact us
Click here to find the right sensorX
  •  
    RM9 with Chopper | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9 with Chopper

    7Y70669
    • Ø8mm
    • 0.15-12µm
    • 100nW-100mW
    • N.A.
    • N.A.
    • Ø62 W x 21 D (mm)
    The RM9 radiometer system is a sensor and optical beam chopper combination for measuring the power of very low level CW or quasi CW light sources. The RM9 sensor has a pyroelectric element to measure a wide dynamic range of radiation, from <100nW to 100mW. It has an 8mm aperture and covers the spectral range from 0.15µm to 12µm. The system comes with the RMC1 chopper that is placed between the source and the RM9 sensor. The chopper should be mounted with the side marked "THIS SIDE TOWARD SENSOR" facing the sensor.
    More info
  •  
    RM9-THz with Chopper | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9-THz with Chopper

    7Y70678
    • Ø8mm
    • 0.1-30THz
    • 100nW-100mW
    • N.A.
    • N.A.
    • Ø62 W x 21 D (mm)
    The RM9-THz radiometer system is a sensor and optical beam chopper combination for measuring the power of very low level CW or quasi CW light sources. This sensor was specially designed for work in the terahertz range. The RM9-THz sensor has a pyroelectric element to measure a wide dynamic range of radiation, from 100nW to 100mW. It has an 8mm aperture and covers the spectral range from 0.1THz to 30THz. The system comes with the RMC1 chopper that is placed between the source and the RM9 sensor. The chopper should be mounted with the side marked "THIS SIDE TOWARD SENSOR" facing the sensor.
    More info
  •  
    RM9-PD with Chopper | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9-PD with Chopper

    7Y70672
    • Ø10mm
    • 0.2-1.1µm
    • 300fW-300nW
    • N.A.
    • N.A.
    • Ø62 W x 22 D (mm)
    The RM9-PD radiometer system is a sensor and optical chopper system for measuring the power of very low level CW or quasi CW sources. The RM9-PD sensor has a photodiode element. The sensor's The sensor's power range is from 300fW (femtowatt) to 300nW (nanowatt). It has an 10mm aperture and covers the spectral range from 0.2µm to 1.1µm. The system comes with the RMC1 chopper that is placed between the source and the RM9-PD sensor. The chopper should be mounted with the side marked "THIS SIDE TOWARD SENSOR" facing the sensor.
    More info
  •  
    RM9 sensor | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9 Pyro Radiometer with Lock-In

    7Z02952
    • Ø8mm
    • 0.15-12µm
    • 100nW-100mW
    • N.A.
    • N.A.
    • Ø62 W x 21 D (mm)
    The RM9 radiometer is a sensor for measuring the power of very low level CW or quasi CW lasers and light sources. The RM9 uses a pyroelectric sensor and lock-in amplifier with an 18Hz chopper (not included, use RMC1 or other chopper) to measure a wide range of radiation, from <100nW to 100mW. It has an 8mm aperture and covers the spectral range from 0.15µm to 12µm.
    More info
  •  
    RM9-THz Pyro Radiometer w/ Lock-In | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9-THz Pyro Radiometer

    7Z02956
    • Ø8mm
    • 0.1-30THz
    • 100nW-100mW
    • N.A.
    • N.A.
    • Ø62 W x 21 D (mm)
    The RM9-THz radiometer is a sensor for measuring the power of very low level CW or quasi CW lasers and light sources. This sensor was specially designed for work in the terahertz range. The RM9-THz uses a pyroelectric sensor and lock-in amplifier with an 18Hz chopper (not included, use RMC1 or other chopper). The power range of the RM9-THz is from 100nW to 100mW, it has an 8mm aperture and covers the spectral range from 0.1THz to 30THz.
    More info
  •  
    RM9-PD sensor | Laser Thermal Power Sensors | Power Sensors - Ophir

    RM9-PD Femtowatt Measurement

    7Z02953
    • Ø10mm
    • 0.2-1.1µm
    • 300fW-300nW
    • N.A.
    • N.A.
    • Ø62 W x 22 D (mm)
    The RM9-PD radiometer is a calibrated sensor for measuring the power of femtowatt CW or quasi CW lasers and light sources. The RM9-PD uses a photodiode sensor in conjunction with an 18Hz chopper (not included, use RMC1 or other chopper). The sensor's power range is from 300fW (femtowatt) to 300nW (nanowatt). It has an 8mm aperture and covers the spectral range from 0.2µm to 1.1µm.
    More info
  •  
    2A-BB-9 | Laser Thermal Power Sensors | Power Sensors - Ophir

    2A-BB-9

    7Z02767
    • Ø9.5mm
    • 0.19-20µm
    • 20µW-2W
    • 20µJ-2J
    • N.A.
    • Ø40 W x 51 D (mm)
    2A-BB-9 is a very sensitive laser power/energy sensor with very low noise and drift. It has a 9.5mm aperture. It can measure from 20µW to 2W and from 10µJ to 2J. It is spectrally flat and covers the spectral range from 0.19 to 20 µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A

    7Z02621
    • Ø9.5mm
    • 0.19-20µm
    • 10µW-3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    3A is a very sensitive thermopile based laser power/energy sensor with very low noise and drift. It has a 9.5mm aperture. It can measure from 10µW to 3W and from 20µJ to 2J. It is spectrally flat and covers the spectral range from 0.19 to 20 µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A-QUAD | BeamTrack Power / Position / Size Sensors | Power Sensors - Ophir

    3A-QUAD

    7Z07934
    • Ø9.5mm
    • 0.19-20µm
    • 100µW-3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The BeamTrack series 3A-QUAD laser measurement sensor measures laser beam position well as power and energy. It has a 9.5mm aperture and can measure beam position to 0.15mm accuracy. It measures power from 100µW to 3W and energy from 20µJ to 2J. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.
    More info
  •  
    3A-P | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A-P

    7Z02622
    • Ø12mm
    • 0.15-8µm
    • 15µW-3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The 3A-P is a very sensitive thermal power/energy laser measurement sensor for short pulsed lasers. It has a 12mm aperture. It can measure from 15µW to 3W and from 20µJ to 2J. It has the P type volume absorber and covers the spectral range from 0.15 to 8µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A-P-QUAD | BeamTrack Power / Position / Size Sensors | Power Sensors - Ophir

    3A-P-QUAD

    7Z07935
    • Ø12mm
    • 0.15-8µm
    • 160µW-3W
    • 30µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The BeamTrack series 3A-P-QUAD laser measurement sensor measures laser beam position well as power and energy. It has a 12mm aperture and can measure beam position to 0.15mm accuracy. It measures power from 160µW to 3W and energy from 30µJ to 2J. It has the P type volume absorber that covers the spectral range from 0.15 to 8µm. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.
    More info
  •  
    3A-PF-12 | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A-PF-12

    7Z02720
    • Ø12mm
    • 0.15-20µm
    • 15µW-3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The 3A-PF-12 is a very sensitive thermal power/energy laser measurement sensor for short pulsed lasers. It has a 12mm aperture. It can measure from 15µW to 3W and from 20µJ to 2J. It has a damage threshold of up to 1.5J/cm2 for ns pulses and covers the spectral range from 0.15 to 20µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A-P-THz | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A-P-THz

    7Z02742
    • Ø12mm
    • 0.1THz-30THz
    • 15µW-3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The 3A-P-THz is a very sensitive thermal power/energy laser measurement sensor with calibration for terahertz wavelengths. It has a 12mm aperture. It can measure from 15µW to 3W and from 20µJ to 2J. It is calibrated for the spectral range 0.1THz - 30THz. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A-FS | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A-FS

    7Z02628
    • Ø9.5mm
    • 0.19-20µm
    • 8µW-3W
    • 15µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The 3A-FS is our lowest noise thermal power/energy laser measurement sensor and has a fused silica window. It has a 9.5mm aperture and can measure from 8µW to 3W and from 15µJ to 2J. It covers the spectral range from 0.19 to 2.2µm with window installed and to 20µm with window removed. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    3A-P-FS-12 | Laser Thermal Power Sensors | Power Sensors - Ophir

    3A-P-FS-12

    7Z02687
    • Ø12mm
    • 0.22 - 2.1µm
    • 15µW - 3W
    • 20µJ-2J
    • N.A.
    • Ø70 W x 30 D (mm)
    The 3A-P-FS-12 is a very sensitive thermal power/energy laser measurement sensor for divergent beams and has a fused silica window. It has a 12mm aperture and can measure from 15µW to 3W and from 20µJ to 2J. Its P type absorber is spectrally flat and covers the spectral range from 0.22 to 2.1µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    12A | Laser Thermal Power Sensors | Power Sensors - Ophir

    12A

    7Z02638
    • Ø16mm
    • 0.19-20µm
    • 2mW-12W
    • 1mJ-30J
    • N.A.
    • Ø80 W x 38 D (mm)
    The 12A is a sensitive thermal power/energy laser measurement sensor with low noise and drift. It has a 16mm aperture. It can measure from 2mW to 12W and from 1mJ to 30J. It has the spectrally flat low power broadband absorber and covers the spectral range from 0.19 to 20µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info
  •  
    12A-P | Laser Thermal Power Sensors | Power Sensors - Ophir

    12A-P

    7Z02624
    • Ø16mm
    • 0.15-8µm
    • 2mW-12W
    • 1mJ-30J
    • N.A.
    • Ø80 W x 38 D (mm)
    The 12A-P is a sensitive thermal power/energy laser measurement sensor for short pulsed lasers with low noise and drift. It has a 16mm aperture and can measure from 2mW to 12W and from 1mJ to 30J. It has the P type volume absorber and covers the spectral range from 0.15 to 8µm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.
    More info

Contact Us

How can we help you?

Send us your information and we will assist you as quickly as we can.

(* Indicates required field)

Laser Power & Energy measurement

Laser Beam Profiling

LED Measurement

Sensor Finder

Meter Finder

Solutions

Beam Profiler Finder

Power Meter Software Solutions

Profiler Selection Chart

Beam Profiling Software

Repair and Recalibration - RMA

Knowledge Center

Calculators

Power Meter Catalog Download

Beam Profiling Catalog Download

Power Meters Distributors

Beam Profiler Distributors

Calibration Centers

  • Contact Us
  • Terms and Conditions
  • Laser calibration
  • Privacy
  • Site Map
  • Newport