WB-I VIS

 
概要: 
  • UV-VIS-NIR (350-1100nm) 波長範囲
  • 付属のNDフィルターによる減衰(ND1および2 X ND3))
  • Ophir標準  SP932Uカメラ(別売り)で動作します

仕様

  • 350-1100nm
  • 10mm–45mm
  • Ø45mm
  • < 70
  • up to 200W (CW), 1000W for 1 minute
ビームプロファイラの選定は ビームプロファイラ・ウィザードをご利用ください。

製品概要

  • Wide Beam Imager VIS

    SP90612

    Accessory for Beam profiling of diverging and large beams

    御見積り

FAQ

BeamGage is giving me results that are very different than expected.

Verify that the Optical Scaling (Magnification) is set to the correct value, as listed on the label of the WB-I unit

Was this FAQ helpful to you? yes no
閉じる

Can it measure smaller diameters than specified 10mm?

Yes, but the accuracy will be lower than what is listed in the specification.

Was this FAQ helpful to you? yes no
閉じる

What is the maximum power?

System absorbs 20% of the power, the other 80% is back diffused from the WB-I. 200W is acceptable in continuous mode; higher power depends on environmental conditions and time of use.

Was this FAQ helpful to you? yes no
閉じる

Can I use different ND filters?

The WB-I is optically aligned and calibrated for use with of any combination of 2 Ophir ND1 or ND3 filters. Other filters have a different thickness and use of them will affect the measurement accuracy

Was this FAQ helpful to you? yes no
閉じる

アクセサリ

上記製品に対応するアクセサリを各種ご用意しております
  • LBS-400 Attenuator
    LBS-400 ビームサンプラーはPyrocam -パイロカムカメラ用の減衰光学系で、最大ビーム径25.4mm、パワーレンジ10mW-500W(1)の紫外 / 赤外レーザーのビームプロファイル計測に対応。LBS-400では、1枚のウェッジで生じる反射偏光成分の変化を相殺するよう設計されており、元のビームの偏光特性が維持されたままビームイメージング。 (1)For Gaussian beam diameter <1/2 the clear aperture and depending on ND filter and camera saturation limits the maximum power may be as high as 1200W.