{"id":671,"date":"2011-09-14T11:47:09","date_gmt":"2011-09-14T11:47:09","guid":{"rendered":"https:\/\/www.ophiropt.com\/blog\/laser-measurement\/?p=671"},"modified":"2025-10-19T18:58:01","modified_gmt":"2025-10-19T18:58:01","slug":"how-to-measure-a-low-power-broadband-light-source","status":"publish","type":"post","link":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/","title":{"rendered":"How to measure a low power broadband light source?"},"content":{"rendered":"<p>Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light sources?<\/p>\n<p><a href=\"https:\/\/www.ophiropt.com\/en\/c\/power-meters\" target=\"_blank\" rel=\"noopener\">Laser measurement<\/a> of high-power broadband light sources can easily be measured using standard thermal or pyroelectric sensors. Pyroelectric and thermal sensors generate an electrical current proportional to absorbed heat whether the light creating the heat is broadband or of a single wavelength. Low power sources are usually measured with photodiode sensors. These sensors have a wide variation in sensitivity as a function of wavelength and are usually calibrated to measure a particular wavelength.<\/p>\n<p><!--more--><\/p>\n<p>When the user measures a narrow wavelength source, he selects the wavelength on the laser power meter the photodiode is attached to, and the correct calibration factor is selected to give the correct reading. However, energy\/power of low power broadband light sources cannot be measured in this way, because sensitivity of photodiodes varies strongly with wavelength and since the light source is broadband, there is no unique sensitivity factor to use.<\/p>\n<p><img decoding=\"async\" class=\"alignleft size-medium wp-image-672 lazyload\" title=\"PD300-BB\" data-src=\"\/blog\/wp-content\/uploads\/2011\/09\/PD300-BB-SH-14-9-11-300x54.jpg\" alt=\"\" width=\"300\" height=\"54\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/54;\" \/><\/p>\n<p>In view of the above, Ophir has designed a special sensor to measure the power\/energy measurement of a source with a spectral spread of wavelengths, the PD300-BB. The PD300-BB has a filter mounted on top of the photodiode with opposite characteristics from the photodiode. It is most transmissive to wavelengths to which the photodiode is least sensitive and least transmissive to those wavelengths that the photodiode is most sensitive. The output of the sensor is the product of the photodiode response and the filter response, so the sensor response is approximately flat, i.e. equally sensitive to all wavelengths.<\/p>\n<p>Below is a graph of the corrected sensitivity of the PD300-BB<\/p>\n<p><img decoding=\"async\" width=\"574\" height=\"384\" class=\"aligncenter size-full wp-image-673\" title=\"Image 1\" src=\"\/blog\/wp-content\/uploads\/2011\/09\/\u05d8\u05d1\u05dc\u05d4-14-9-11.bmp\" alt=\"\" \/><\/p>\n<p>For further information,<a href=\"https:\/\/www.ophiropt.com\/en\/laser-measurement\"> contact us<\/a><\/p>\n<p><em>You might also like to read:\u00a0<a title=\"Easy solutions for measuring low power beams\" href=\"\/?p=981\">Easy solutions for measuring low power beams<\/a><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8712,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[5,551,390],"tags":[53],"ophirposttype":[349],"class_list":["post-671","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-laser-power-energy-measurement","category-laser-power-energy-sensors-en-2","category-photodiode-sensors","tag-low-power","ophirposttype-blogpost-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to measure a low power broadband light source? - Ophir Photonics<\/title>\n<meta name=\"description\" content=\"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to measure a low power broadband light source? - Ophir Photonics\" \/>\n<meta property=\"og:description\" content=\"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\" \/>\n<meta property=\"og:site_name\" content=\"Ophir Photonics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\" \/>\n<meta property=\"article:published_time\" content=\"2011-09-14T11:47:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-19T18:58:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"OphirBlog\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"OphirBlog\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\"},\"author\":{\"name\":\"OphirBlog\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\"},\"headline\":\"How to measure a low power broadband light source?\",\"datePublished\":\"2011-09-14T11:47:09+00:00\",\"dateModified\":\"2025-10-19T18:58:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\"},\"wordCount\":312,\"commentCount\":2,\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png\",\"keywords\":[\"Low Power\"],\"articleSection\":[\"Laser Power &amp; Energy Measurement\",\"Laser Power &amp; Energy Sensors\",\"Photodiode sensors\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\",\"name\":\"How to measure a low power broadband light source? - Ophir Photonics\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png\",\"datePublished\":\"2011-09-14T11:47:09+00:00\",\"dateModified\":\"2025-10-19T18:58:01+00:00\",\"description\":\"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png\",\"width\":800,\"height\":350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ophiropt.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to measure a low power broadband light source?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"name\":\"Ophir Photonics\",\"description\":\"Laser Measurement Blog\",\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\",\"name\":\"Ophir Photonics\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"width\":316,\"height\":57,\"caption\":\"Ophir Photonics\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\",\"https:\/\/www.instagram.com\/ophir_by_mks\/\",\"https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true\",\"https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\",\"name\":\"OphirBlog\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"caption\":\"OphirBlog\"},\"url\":\"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to measure a low power broadband light source? - Ophir Photonics","description":"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/","og_locale":"en_US","og_type":"article","og_title":"How to measure a low power broadband light source? - Ophir Photonics","og_description":"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light","og_url":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/","og_site_name":"Ophir Photonics","article_publisher":"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","article_published_time":"2011-09-14T11:47:09+00:00","article_modified_time":"2025-10-19T18:58:01+00:00","og_image":[{"width":800,"height":350,"url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png","type":"image\/png"}],"author":"OphirBlog","twitter_card":"summary_large_image","twitter_misc":{"Written by":"OphirBlog","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#article","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/"},"author":{"name":"OphirBlog","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b"},"headline":"How to measure a low power broadband light source?","datePublished":"2011-09-14T11:47:09+00:00","dateModified":"2025-10-19T18:58:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/"},"wordCount":312,"commentCount":2,"publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png","keywords":["Low Power"],"articleSection":["Laser Power &amp; Energy Measurement","Laser Power &amp; Energy Sensors","Photodiode sensors"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/","url":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/","name":"How to measure a low power broadband light source? - Ophir Photonics","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png","datePublished":"2011-09-14T11:47:09+00:00","dateModified":"2025-10-19T18:58:01+00:00","description":"Photodiodes are usually used to measure the power and energy of low power laser beams. Can photodiodes be used to measure low power broadband light","breadcrumb":{"@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#primaryimage","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2011\/12\/bc20.png","width":800,"height":350},{"@type":"BreadcrumbList","@id":"https:\/\/www.ophiropt.com\/blog\/how-to-measure-a-low-power-broadband-light-source\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ophiropt.com\/blog\/"},{"@type":"ListItem","position":2,"name":"How to measure a low power broadband light source?"}]},{"@type":"WebSite","@id":"https:\/\/www.ophiropt.com\/blog\/#website","url":"https:\/\/www.ophiropt.com\/blog\/","name":"Ophir Photonics","description":"Laser Measurement Blog","publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ophiropt.com\/blog\/#organization","name":"Ophir Photonics","url":"https:\/\/www.ophiropt.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","width":316,"height":57,"caption":"Ophir Photonics"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","https:\/\/www.instagram.com\/ophir_by_mks\/","https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber"]},{"@type":"Person","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b","name":"OphirBlog","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","caption":"OphirBlog"},"url":"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/comments?post=671"}],"version-history":[{"count":1,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/671\/revisions"}],"predecessor-version":[{"id":35313,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/671\/revisions\/35313"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media\/8712"}],"wp:attachment":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media?parent=671"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/categories?post=671"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/tags?post=671"},{"taxonomy":"ophirposttype","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/ophirposttype?post=671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}