{"id":14446,"date":"2024-11-20T11:00:00","date_gmt":"2024-11-20T11:00:00","guid":{"rendered":"https:\/\/blog.ophiropt.com\/?p=14446"},"modified":"2024-11-18T08:17:25","modified_gmt":"2024-11-18T08:17:25","slug":"preventing-sensor-deterioration","status":"publish","type":"post","link":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/","title":{"rendered":"Preventing Sensor Deterioration"},"content":{"rendered":"\n<p>They say that an ounce of prevention is worth a pound of cure. And the same goes for your <a href=\"https:\/\/www.ophiropt.com\/en\/c\/thermopile-sensors\">thermal sensors.<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image alignright size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"350\" data-src=\"https:\/\/blog.ophiropt.com\/wp-content\/uploads\/2024\/05\/blog-feature-images-new-design-45-1.png\" alt=\"\" class=\"wp-image-14635 lazyload\" style=\"--smush-placeholder-width: 800px; --smush-placeholder-aspect-ratio: 800\/350;width:326px;height:auto\" data-srcset=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/blog-feature-images-new-design-45-1.png 800w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/blog-feature-images-new-design-45-1-322x141.png 322w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/blog-feature-images-new-design-45-1-768x336.png 768w\" data-sizes=\"(max-width: 800px) 100vw, 800px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" \/><\/figure>\n\n\n\n<p>Sometimes, you can use your thermal sensors for <strong><em>years<\/em><\/strong> without the need for repairs. But <strong><em>when<\/em><\/strong> we receive these sensors for calibration, we can often tell that misuse led to the sensor\u2019s deterioration. <br>Here are 3 things that can help prevent deterioration of your thermal sensors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>A surface that remains clean from contamination<\/strong><\/h2>\n\n\n\n<p>Firstly, keep the sensor disc clean from foreign substances, such as process debris from industrial environments, or organic contaminants that can then be burned onto the disc by subsequent exposure to a laser beam.<\/p>\n\n\n\n<p>So, keep the surface clean and store the sensor properly when it isn\u2019t being used.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>Causing overheating<\/strong><\/h2>\n\n\n\n<p>The second cause of deterioration comes when the sensor disc is used at a power level higher than specified, causing overheating.<\/p>\n\n\n\n<p>Major overheating can destroy the detecting element, but even moderate overheating can cause damage to the absorber coating; both will require replacement of the disc.<\/p>\n\n\n\n<p>So, avoid overheating by using the <strong><em>right<\/em><\/strong> power levels for continuous use versus those for short term use.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>Localized overheating of the coating<\/strong><\/h2>\n\n\n\n<p>Finally, the third cause of sensor deterioration is <strong><em>localized<\/em> <\/strong>overheating of the coating. It\u2019s the <strong><em>number one<\/em><\/strong> cause for disc replacement.<\/p>\n\n\n\n<p>Every coating type has a specific power and energy damage threshold. The spec sheet for each sensor offers guidance on the limits for power and energy damage. Try to stay within those guidelines. <br>If you follow this advice, it can definitely help prevent the deterioration of your thermal sensor. Read more useful tips on our <a href=\"https:\/\/blog.ophiropt.com\/how-to-avoid-damage-to-your-thermal-sensors\/\">blog<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":14637,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[548,551],"tags":[63],"ophirposttype":[349],"class_list":["post-14446","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-laser-power-energy-meters-en","category-laser-power-energy-sensors-en-2","tag-power-sensors","ophirposttype-blogpost-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Preventing Sensor Deterioration - Ophir Photonics<\/title>\n<meta name=\"description\" content=\"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Preventing Sensor Deterioration - Ophir Photonics\" \/>\n<meta property=\"og:description\" content=\"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\" \/>\n<meta property=\"og:site_name\" content=\"Ophir Photonics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-20T11:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"OphirBlog\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"OphirBlog\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\"},\"author\":{\"name\":\"OphirBlog\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\"},\"headline\":\"Preventing Sensor Deterioration\",\"datePublished\":\"2024-11-20T11:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\"},\"wordCount\":276,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png\",\"keywords\":[\"Power Sensors\"],\"articleSection\":[\"Laser Power &amp; Energy Meters\",\"Laser Power &amp; Energy Sensors\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\",\"name\":\"Preventing Sensor Deterioration - Ophir Photonics\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png\",\"datePublished\":\"2024-11-20T11:00:00+00:00\",\"description\":\"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png\",\"width\":1200,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ophiropt.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Preventing Sensor Deterioration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"name\":\"Ophir Photonics\",\"description\":\"Laser Measurement Blog\",\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\",\"name\":\"Ophir Photonics\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"width\":316,\"height\":57,\"caption\":\"Ophir Photonics\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\",\"https:\/\/www.instagram.com\/ophir_by_mks\/\",\"https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true\",\"https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\",\"name\":\"OphirBlog\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"caption\":\"OphirBlog\"},\"url\":\"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Preventing Sensor Deterioration - Ophir Photonics","description":"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/","og_locale":"en_US","og_type":"article","og_title":"Preventing Sensor Deterioration - Ophir Photonics","og_description":"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for","og_url":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/","og_site_name":"Ophir Photonics","article_publisher":"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","article_published_time":"2024-11-20T11:00:00+00:00","og_image":[{"width":1200,"height":600,"url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png","type":"image\/png"}],"author":"OphirBlog","twitter_card":"summary_large_image","twitter_misc":{"Written by":"OphirBlog","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#article","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/"},"author":{"name":"OphirBlog","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b"},"headline":"Preventing Sensor Deterioration","datePublished":"2024-11-20T11:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/"},"wordCount":276,"commentCount":0,"publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png","keywords":["Power Sensors"],"articleSection":["Laser Power &amp; Energy Meters","Laser Power &amp; Energy Sensors"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/","url":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/","name":"Preventing Sensor Deterioration - Ophir Photonics","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png","datePublished":"2024-11-20T11:00:00+00:00","description":"They say that an ounce of prevention is worth a pound of cure. And the same goes for your thermal sensors. Sometimes, you can use your thermal sensors for","breadcrumb":{"@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#primaryimage","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/05\/New-blog-cover-1200-x-600-px-9.png","width":1200,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.ophiropt.com\/blog\/preventing-sensor-deterioration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ophiropt.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Preventing Sensor Deterioration"}]},{"@type":"WebSite","@id":"https:\/\/www.ophiropt.com\/blog\/#website","url":"https:\/\/www.ophiropt.com\/blog\/","name":"Ophir Photonics","description":"Laser Measurement Blog","publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ophiropt.com\/blog\/#organization","name":"Ophir Photonics","url":"https:\/\/www.ophiropt.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","width":316,"height":57,"caption":"Ophir Photonics"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","https:\/\/www.instagram.com\/ophir_by_mks\/","https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber"]},{"@type":"Person","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b","name":"OphirBlog","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","caption":"OphirBlog"},"url":"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/14446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/comments?post=14446"}],"version-history":[{"count":0,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/14446\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media\/14637"}],"wp:attachment":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media?parent=14446"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/categories?post=14446"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/tags?post=14446"},{"taxonomy":"ophirposttype","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/ophirposttype?post=14446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}