{"id":11633,"date":"2022-12-21T11:00:11","date_gmt":"2022-12-21T11:00:11","guid":{"rendered":"https:\/\/blog.ophiropt.com\/?p=11633"},"modified":"2024-02-22T12:11:16","modified_gmt":"2024-02-22T12:11:16","slug":"high-power-lasers-and-industry-4-0-focusing-on-knowledge","status":"publish","type":"post","link":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/","title":{"rendered":"High-Power Lasers and Industry 4.0: Focusing on Knowledge"},"content":{"rendered":"\n<p>A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have Profinet interfaces and allow the processes to be documented. These are enormous advantages, especially in times of just-in-time production.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">The challenge &#8211;  everything has to fit perfectly  <\/h4>\n\n\n\n<p><a href=\"https:\/\/www.ophiropt.com\/en\/s\/automotive\">Automated laser welding<\/a> is a big topic in modern production and more and more new applications are being developed.&nbsp; Be it pairing materials that were previously considered to be non-weldable, complex contours or extremely stressed components, a good deal of specialist knowledge is always required; after all, everything has to fit perfectly, from material properties to clamping technology and laser beam. This also applies to the measurement technology used for quality assurance. <\/p>\n\n\n\n<p>The weld seam itself can only be checked by random samples where material is destroyed or by time and cost-intensive ultrasound tests. If weaknesses are actually found during such an inspection, the bad parts must be sorted out after all costs of the value chain have already been incurred. <br>It is significantly cheaper to proactively ensure the consistent quality of weld seams. The joining gap caused by the clamping process and the position of the weld seam are often checked by cameras or laser triangulation sensors, but exact compliance with the defined specifications of the focused laser beam itself is a challenge at high power densities. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">All-in-One Sensors<\/h4>\n\n\n\n<p>MKS Instruments developed the robust and compact performance measuring device <a href=\"https:\/\/www.ophiropt.com\/en\/f\/helios-plus-industrial-power-sensors\">Ophir Helios<\/a> to be specifically used in automated production, which, for less critical applications, provides reliable clues as to whether the basic parameters for the precise implementation of weld seams can be observed. <\/p>\n\n\n\n<figure class=\"wp-block-image alignright\"><img decoding=\"async\" width=\"231\" height=\"197\" data-src=\"https:\/\/blog.ophiropt.com\/wp-content\/uploads\/2021\/11\/image-3.png\" alt=\"\" class=\"wp-image-11635 lazyload\" data-srcset=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/11\/image-3.png 231w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/11\/image-3-181x154.png 181w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/11\/image-3-24x20.png 24w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/11\/image-3-36x31.png 36w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/11\/image-3-48x41.png 48w\" data-sizes=\"(max-width: 231px) 100vw, 231px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 231px; --smush-placeholder-aspect-ratio: 231\/197;\" \/><figcaption class=\"wp-element-caption\"> Fig. 1: The robust and compact performance measuring device Helios was developed for use in automated production. <\/figcaption><\/figure>\n\n\n\n<p>The measuring device measures the power and energy of industrial diodes, fiber or Nd:YAG lasers during a short irradiation time between 0.1 and 10s and uses this to calculate the total power up to a maximum of 12 kW or total energy up to 10 kJ. If the measured values lie outside the process window defined by the user, intervention is required.<\/p>\n\n\n\n<p>For further reading please click <a href=\"https:\/\/www.ophiropt.com\/en\/n\/lasers-and-industry\">here<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12679,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[321,5,323],"tags":[],"ophirposttype":[349],"class_list":["post-11633","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industrial-applications","category-laser-power-energy-measurement","category-material-processing","ophirposttype-blogpost-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics<\/title>\n<meta name=\"description\" content=\"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics\" \/>\n<meta property=\"og:description\" content=\"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\" \/>\n<meta property=\"og:site_name\" content=\"Ophir Photonics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-21T11:00:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-22T12:11:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"OphirBlog\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"OphirBlog\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\"},\"author\":{\"name\":\"OphirBlog\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\"},\"headline\":\"High-Power Lasers and Industry 4.0: Focusing on Knowledge\",\"datePublished\":\"2022-12-21T11:00:11+00:00\",\"dateModified\":\"2024-02-22T12:11:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\"},\"wordCount\":364,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png\",\"articleSection\":[\"Industrial Applications\",\"Laser Power &amp; Energy Measurement\",\"Material Processing Application\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\",\"name\":\"High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png\",\"datePublished\":\"2022-12-21T11:00:11+00:00\",\"dateModified\":\"2024-02-22T12:11:16+00:00\",\"description\":\"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png\",\"width\":800,\"height\":350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ophiropt.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"High-Power Lasers and Industry 4.0: Focusing on Knowledge\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"name\":\"Ophir Photonics\",\"description\":\"Laser Measurement Blog\",\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\",\"name\":\"Ophir Photonics\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"width\":316,\"height\":57,\"caption\":\"Ophir Photonics\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\",\"https:\/\/www.instagram.com\/ophir_by_mks\/\",\"https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true\",\"https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\",\"name\":\"OphirBlog\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"caption\":\"OphirBlog\"},\"url\":\"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics","description":"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/","og_locale":"en_US","og_type":"article","og_title":"High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics","og_description":"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have","og_url":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/","og_site_name":"Ophir Photonics","article_publisher":"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","article_published_time":"2022-12-21T11:00:11+00:00","article_modified_time":"2024-02-22T12:11:16+00:00","og_image":[{"width":800,"height":350,"url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png","type":"image\/png"}],"author":"OphirBlog","twitter_card":"summary_large_image","twitter_misc":{"Written by":"OphirBlog","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#article","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/"},"author":{"name":"OphirBlog","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b"},"headline":"High-Power Lasers and Industry 4.0: Focusing on Knowledge","datePublished":"2022-12-21T11:00:11+00:00","dateModified":"2024-02-22T12:11:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/"},"wordCount":364,"commentCount":0,"publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png","articleSection":["Industrial Applications","Laser Power &amp; Energy Measurement","Material Processing Application"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/","url":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/","name":"High-Power Lasers and Industry 4.0: Focusing on Knowledge - Ophir Photonics","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png","datePublished":"2022-12-21T11:00:11+00:00","dateModified":"2024-02-22T12:11:16+00:00","description":"A new measurement procedure allows for the fast and contact-free measurement of the focused laser beam. At the same time, modern measuring devices have","breadcrumb":{"@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#primaryimage","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2023\/01\/blog-feature-images-new-design-5.png","width":800,"height":350},{"@type":"BreadcrumbList","@id":"https:\/\/www.ophiropt.com\/blog\/high-power-lasers-and-industry-4-0-focusing-on-knowledge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ophiropt.com\/blog\/"},{"@type":"ListItem","position":2,"name":"High-Power Lasers and Industry 4.0: Focusing on Knowledge"}]},{"@type":"WebSite","@id":"https:\/\/www.ophiropt.com\/blog\/#website","url":"https:\/\/www.ophiropt.com\/blog\/","name":"Ophir Photonics","description":"Laser Measurement Blog","publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ophiropt.com\/blog\/#organization","name":"Ophir Photonics","url":"https:\/\/www.ophiropt.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","width":316,"height":57,"caption":"Ophir Photonics"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","https:\/\/www.instagram.com\/ophir_by_mks\/","https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber"]},{"@type":"Person","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b","name":"OphirBlog","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","caption":"OphirBlog"},"url":"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/11633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/comments?post=11633"}],"version-history":[{"count":0,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/11633\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media\/12679"}],"wp:attachment":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media?parent=11633"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/categories?post=11633"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/tags?post=11633"},{"taxonomy":"ophirposttype","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/ophirposttype?post=11633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}