{"id":10319,"date":"2021-10-27T11:00:41","date_gmt":"2021-10-27T11:00:41","guid":{"rendered":"https:\/\/www.ophiropt.com\/blog\/laser-measurement\/?p=10319"},"modified":"2024-02-29T09:53:31","modified_gmt":"2024-02-29T09:53:31","slug":"understanding-the-specs-power-meter-damage-threshold-shafner","status":"publish","type":"post","link":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/","title":{"rendered":"Understanding the Specs:  Power Meter Damage Threshold"},"content":{"rendered":"\n<p>When choosing and using a <a href=\"https:\/\/www.ophiropt.com\/en\/laser-measurement\">power meter<\/a> to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold.<\/p>\n\n\n\n<p>As defined by\nOphir, this is the point at which the reading is altered by at least 1% from\nits original performance (although there may be no noticeable damage).<\/p>\n\n\n\n<p>There are two ways to check the damage threshold of your Ophir power sensor. The most straightforward method is looking it up in its specifications sheet, on the website, or in the <a href=\"https:\/\/www.ophiropt.com\/en\/resourceListing\/all\/laser-measurement?facetName=ResourceCategory&amp;q=%3Arelevance%3Aresourcecategory%3ALaser+Measurement%3AresourceType%3ACatalogs&amp;text=\">Ophir catalog<\/a>. All of these should show you the same value, in units of W\/cm<sup>2<\/sup>.<\/p>\n\n\n\n<p>The other way to find the damage threshold of your sensor might be less intuitive. Search in the <a href=\"https:\/\/www.ophiropt.com\/en\/laser-sensor-finder\">sensor finder<\/a> according to your laser\u2019s parameters (power, energy, wavelength, etc.). Scroll through the resulting suggested sensors to find yours. You will notice that among other pieces of information, each sensor has a \u201c% of damage threshold\u201d value. This is useful in determining how suitable a sensor is for any given laser. As a rule of thumb, we recommend keeping it below 50% of the damage threshold as a margin of safety.<\/p>\n\n\n\n<p>If you do the\nmath, however, you might notice something puzzling. The damage threshold\nextrapolated from the sensor finder doesn\u2019t match the figure in the\nspecifications. The reason behind this is that the catalog can only state one\nvalue, while the sensor finder can have detailed and precise calculations\nperformed on the backend. Among other things, the sensor finder will take into\naccount other factors like wavelength and exposure time. The catalog and spec\nsheet are limited to take a (usually conservative) generic value.<\/p>\n\n\n\n<p>Both are correct and will provide you with ample margin for error. That said, if you want the most precise damage threshold possible, extrapolate it from the <a href=\"https:\/\/www.ophiropt.com\/en\/laser-sensor-finder\">sensor finder<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"973\" height=\"568\" data-src=\"https:\/\/blog.ophiropt.com\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec.png\" alt=\"Sensor finder vs. spec\" class=\"wp-image-11601 lazyload\" data-srcset=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec.png 973w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec-300x175.png 300w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec-768x448.png 768w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec-24x14.png 24w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec-36x21.png 36w, https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Sensor-finder-vs.-spec-48x28.png 48w\" data-sizes=\"(max-width: 973px) 100vw, 973px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 973px; --smush-placeholder-aspect-ratio: 973\/568;\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":11602,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[5],"tags":[56],"ophirposttype":[349],"class_list":["post-10319","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-laser-power-energy-measurement","tag-meters","ophirposttype-blogpost-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics<\/title>\n<meta name=\"description\" content=\"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics\" \/>\n<meta property=\"og:description\" content=\"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\" \/>\n<meta property=\"og:site_name\" content=\"Ophir Photonics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-10-27T11:00:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-29T09:53:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"OphirBlog\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"OphirBlog\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\"},\"author\":{\"name\":\"OphirBlog\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\"},\"headline\":\"Understanding the Specs: Power Meter Damage Threshold\",\"datePublished\":\"2021-10-27T11:00:41+00:00\",\"dateModified\":\"2024-02-29T09:53:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\"},\"wordCount\":311,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png\",\"keywords\":[\"Meters\"],\"articleSection\":[\"Laser Power &amp; Energy Measurement\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\",\"name\":\"Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics\",\"isPartOf\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png\",\"datePublished\":\"2021-10-27T11:00:41+00:00\",\"dateModified\":\"2024-02-29T09:53:31+00:00\",\"description\":\"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png\",\"width\":800,\"height\":350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ophiropt.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding the Specs: Power Meter Damage Threshold\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#website\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"name\":\"Ophir Photonics\",\"description\":\"Laser Measurement Blog\",\"publisher\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#organization\",\"name\":\"Ophir Photonics\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg\",\"width\":316,\"height\":57,\"caption\":\"Ophir Photonics\"},\"image\":{\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/\",\"https:\/\/www.instagram.com\/ophir_by_mks\/\",\"https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true\",\"https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b\",\"name\":\"OphirBlog\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"url\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"contentUrl\":\"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg\",\"caption\":\"OphirBlog\"},\"url\":\"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics","description":"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/","og_locale":"en_US","og_type":"article","og_title":"Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics","og_description":"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As","og_url":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/","og_site_name":"Ophir Photonics","article_publisher":"https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","article_published_time":"2021-10-27T11:00:41+00:00","article_modified_time":"2024-02-29T09:53:31+00:00","og_image":[{"width":800,"height":350,"url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png","type":"image\/png"}],"author":"OphirBlog","twitter_card":"summary_large_image","twitter_misc":{"Written by":"OphirBlog","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#article","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/"},"author":{"name":"OphirBlog","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b"},"headline":"Understanding the Specs: Power Meter Damage Threshold","datePublished":"2021-10-27T11:00:41+00:00","dateModified":"2024-02-29T09:53:31+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/"},"wordCount":311,"commentCount":0,"publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png","keywords":["Meters"],"articleSection":["Laser Power &amp; Energy Measurement"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/","url":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/","name":"Understanding the Specs: Power Meter Damage Threshold - Ophir Photonics","isPartOf":{"@id":"https:\/\/www.ophiropt.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png","datePublished":"2021-10-27T11:00:41+00:00","dateModified":"2024-02-29T09:53:31+00:00","description":"When choosing and using a power meter to measure your laser, one of the most critical specifications to understand is the sensor\u2019s damage threshold. As","breadcrumb":{"@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#primaryimage","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2021\/10\/Understanding-the-Specs-Power-Meter-Damage-Threshold.png","width":800,"height":350},{"@type":"BreadcrumbList","@id":"https:\/\/www.ophiropt.com\/blog\/understanding-the-specs-power-meter-damage-threshold-shafner\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ophiropt.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Understanding the Specs: Power Meter Damage Threshold"}]},{"@type":"WebSite","@id":"https:\/\/www.ophiropt.com\/blog\/#website","url":"https:\/\/www.ophiropt.com\/blog\/","name":"Ophir Photonics","description":"Laser Measurement Blog","publisher":{"@id":"https:\/\/www.ophiropt.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ophiropt.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ophiropt.com\/blog\/#organization","name":"Ophir Photonics","url":"https:\/\/www.ophiropt.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/MKS-Ophir_Linear_White-3.svg","width":316,"height":57,"caption":"Ophir Photonics"},"image":{"@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OphirPhotonicsGroup\/","https:\/\/www.instagram.com\/ophir_by_mks\/","https:\/\/www.linkedin.com\/company\/ophir-optronics\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCPvz0KXnZ5LWgO_HC5pO6ow?view_as=subscriber"]},{"@type":"Person","@id":"https:\/\/www.ophiropt.com\/blog\/#\/schema\/person\/d1146bd4d1105af2b2351f3e579b902b","name":"OphirBlog","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","url":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","contentUrl":"https:\/\/www.ophiropt.com\/blog\/wp-content\/uploads\/2024\/03\/avatar-auth-154x154.jpg","caption":"OphirBlog"},"url":"https:\/\/www.ophiropt.com\/blog\/author\/ophirblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/10319","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/comments?post=10319"}],"version-history":[{"count":0,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/posts\/10319\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media\/11602"}],"wp:attachment":[{"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/media?parent=10319"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/categories?post=10319"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/tags?post=10319"},{"taxonomy":"ophirposttype","embeddable":true,"href":"https:\/\/www.ophiropt.com\/blog\/wp-json\/wp\/v2\/ophirposttype?post=10319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}