WaveStar Spectrometers
Unprecedented resolution for a CCD Optical Spectrum Analyzer or Wavemeter - 0.5nm
FWHM Automatically finds and tags peak wavelengths to 0.1nm accuracy
Self contained - plugs into parallel port - no PC card necessary
WaveStar V 570 - 1070nm, WaveStar U 360 - 625nm
Photodiode trigger to capture single shot events
Complete set of fiber adapters and attenuators available.
True NIST traceable intensity vs. wavelength display
ActiveX Components to ease integration into legacy measurment systems

Download the
WaveStar Catalog
Download the
WaveStar software
Frequently Asked
Questions (FAQ)
The Ophir WaveStar introduces a new level of accuracy and ease in spectral measurements. Just plug into your PC parallel port, install the software and easily and accurately measure spectra from a wide variety of sources including continuous and pulsed sources from microwatts to watts in intensity. The program automatically tags the peaks with the wavelength so the result is readily available.



The WaveStar comes with interchangeable filters which together with the variable shutter speed allows you to easily and accurately measure any type of source from fractions of a microwatt to watts in intensity. Fiber adapters are available to connect to fiber sources.

The WaveStar has up to 4 times as high resolution as similar competing instruments due to its innovative optical design (patent applied for). Its innovative peak interpolation algorithms allow you to find the peak wavelengths of lines at up to 10 times the accuracy of competing instruments and at the same time much greater ease. The built in intensity calibration insures that the relative intensity vs. wavelength gives an accurate relative curve. This is especially important when measuring broadband sources such as lamps.

Specifications of WaveStar U and WaveStar V

Item Specification
Detector 3000 element CCD
Optics Proprietary optical design (patent applied for)
Spectral Response: Model WaveStar-V 570 - 1070nm
Model WaveStar-U 360 - 625nm
Wavelength resolution FWHM 0.5nm
Wavelength peak detection Proprietary algorithm interpolates pixels and tags peaks with the wavelength value to an accuracy of 0.1nm. The FWHM of each peak is also shown if desired.
Mounting thread 1/4 Inch threaded mounting hole
Intensity vs. wavelength The intensity display is corrected for variations in system sensitivity with wavelength to give a relative intensity accuracy of ±5% over the spectral region.
Dimensions: 80mm x 70mm x 100mm
Optional accessories SMA fiber adapter, diffusers, ND filters
Connections to PC Connects to standard parallel port via 3 meter cable. No hardware installation in PC is necessary.
Trigger Photodiode trigger allows capture of single shot events.
Minimum host system requirements Pentium 200MHz 32MB RAM 10MB HD free, Windows 95/98, 2MB 16bit color VGA card, one free parallel port
Performance with pulsed sources Operates with continuous or pulsed sources at pulse rates from <1Hz up. Special trigger photodiode allows measurement of single pulse events.


Download the WaveStar software - Now released ver. 1.05 (May 2004)