Photodiode Energy Sensors

Silicon, Germanium Photodiode Energy Sensors | Laser measurement sensor

Photodiode Energy Sensors – 10pJ to 15µJ
Ophir photodiode laser energy sensors are able to measure low energy pulses down to 10pJ at frequencies up to 20KHz. Use Silicon photodiodes for ultraviolet and visible light, and Germanium photodiodes for infrared.

Ordering Info
Sensors Catalog
Accessories
Related Items

Photodiode energy sensors - 10pJ - 15µJ



   SensorFeaturesApertureSpectral RangeEnergy RangeMax. FrequencyP/N
  
PD10-C
Very low energies down to nJ, Silicon photodiode  Ø10mm 0.19-1.1µm 1nJ-15µJ 20,000Hz 7Z02944
  
PD10-pJ-C
Lowest energies down to pJ, Silicon photodiode  Ø10mm 0.2-1.1µm 10pJ-200nJ 20,000Hz 7Z02945
  
PD10-IR-pJ-C
Lowest energies down to pJ, Germanium photodiode for infrared  Ø5mm 0.7-1.8µm 30pJ-20nJ 10,000Hz 7Z02946

Firmware update for the PD10-C series sensors

PD10-C series sensors with StarLab
Support for PD10-C series sensors with Vega, Nova II, Juno and StarLite in StarLab application is now available.
When working with other meters it is not necessary to update the embedded software.
Download Steps
In order to upgrade the embedded software (named "PE-C firmware") in the PD10-C series sensors with the StarLab application:
  • Attach the sensor from the PD10-C series to a Juno (with version 1.21 or higher), a Vega / Nova-II (version 2.16 or higher) or a StarLite (version 1.22 or higher).
    To download the latest version of Juno, Vega, Nova-II or StarLite software press here
  • Connect the meter to the PC and run StarLab (with version 2.10 or higher).
    To download the latest StarLab version press here
  • Enter the diagnostic screen and select to upgrade sensor software (version 1.69 or higher).
    To download the latest PE-C firmware version press here
Catalog - Energy sensors Energy sensors
Energy sensors

pgs. 56-71 (1.36 MB)

Ophir Photonics laser photodiode sensors are useful for laser measurement of the energy of pulsed lasers.

   PhotoNameFeaturesP/N
Ophir Laser Measurement Instruments Thermal sensors - SC Fiber Adapter SC Fiber Adapter
SC Fiber Adapter
SC Fiber adapter  7Z08227
Ophir Laser Measurement Instruments Thermal sensors - LC Fiber Adapter LC Fiber Adapter
ST Fiber Adapter
ST Fiber adapter  7Z08226
Ophir Laser Measurement Instruments Thermal sensors - FC Fiber Adapter FC Fiber Adapter
FC Fiber Adapter
FC Fiber adapter  7Z08229
Ophir Laser Measurement Instruments Thermal sensors - SMA Fiber Adapter SMA Fiber Adapter
SMA Fiber Adapter
SMA Fiber adapter  1G01236
Ophir Laser Measurement IR Laser Phosphor Glass IR Laser Phosphor Glass
IR Laser Phosphor Glass
For visualizing spectral region 810-860nm, 900-1100nm and 1500-1600nm 7F01235A
      Photo Name Features P/N  
           
  Ophir Laser Measurement Instruments     Photodiode sensors - Vega Vega
Vega
Vega color laser power / energy meter for thermal, pyroelectric and photodiode sensors 7Z01560  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Nova II Nova II
Nova II
Nova II laser power / energy meter for thermal, pyroelectric and photodiode sensors 7Z01550  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Nova Nova
Nova
Nova laser power / energy meter for thermal, pyroelectric and photodiode sensors. For the "Nova PE-C Adapter" allowing the Nova to operate with Pyroelectric PE-C series sensors press here. 7Z01500  
         
  StarLite Laser Power Meter StarLite Laser Power Meter
StarLite
StarLite low cost laser power / energy meter for all standard Ophir Thermal, BeamTrack, PE-C Pyroelectric and Photodiode sensors 7Z01565  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - LaserStar LaserStar
LaserStar Single Channel
Laserstar single channel laser power / energy meter for thermal, pyroelectric, photodiode and RP sensors 7Z01600  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - LaserStar LaserStar
LaserStar Dual Channel
The dual channel model enables user to measure two channels independently, or the ratio or difference between them in real time. 7Z01601  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Pulsar 4 Pulsar
Pulsar 4
Fast 4 channels Pulsar with external trigger 7Z01201  
         
  Ophir Laser Measurement Instruments Photodiode sensors - Pulsar 2 Pulsar 2
Pulsar 2
Same as above but for 2 channels only 7Z01202  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Pulsar 1 Pulsar 1
Pulsar 1
Same as above but for single channel 7Z01203  
         
  Ophir Laser Measurement Instruments - Photodiode sensors - USB Interface USBI Interface
USB Interface
Module to operate one Ophir smart sensor from your PC USB port. Comes with a software. Max rep rate for every pulse- 2KHz 7Z01200  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Juno Juno
Juno
Compact USB Interface that turns your PC into an Ophir power & energy meter 7Z01250  
         
  Ophir Laser Measurement Instruments     Photodiode sensors - Quasar Quasar
Quasar
Quasar bluetooth wireless smart sensor to PC interface 7Z01300