LD8900 & LD 8900R

Goniometric Radiometer

LD8900 & LD8900R Beam Profiling Systems for Divergent Light Sources

Profiling divergent light sources presents many challenges, but Photon's far-field profilers characterize the angular radiation intensity of light simply and accurately in real time. Both the LD 8900 and LD 8900R (wide dynamic range Goniometric Radiometer) provide full 3-dimensional measurements of the far-field pattern in minutes or less, with far better resolution than a CCD camera.

    Read more...
    LD 8900 & LD 8900R

    Specification

    • 320nm-1100nm (Silicon), 800-1700nm (InGaAs), 190nm-~1100nm (Optional UV)
    • Silicon, InGaAs, Optional UV
    • 1μW to 1W (Single Mode Fiber), 10's of μW to 10's of W (Multimode Fiber)
    • 2mm standard (optional 1cm)
    Need help finding the right beam profiler? Try our Beam Profiler Wizard

    The Gonimetric Radiometers are available with the following configurations:
    • LD8900/InGaAs

      PH00173

      Goniometric Radiometer for characterizing the angular radiation intensity from a laser diode between 800nm and 1700nm wavelength. Entrance aperture 2mm.

      Request a Quote
    • LD8900/Si

      PH00174

      Goniometric Radiometer for characterizing the angular radiation intensity from a laser diode between 320nm and 1100nm wavelength. Entrance aperture 2mm. Full 3D capability. Features dynamic range >36dB with 0 dB source.

      Request a Quote
    • LD8900R/InGaAs

      PH00175

      Wide Dynamic Range Goniometric Radiometer for characterizing the angular radiation irradiance from a fiber optic, wave guide, laser diode, VCSEL, or LED between 800nm and 1700nm wavelength.

      Request a Quote
    • LD8900R/Si

      PH00176

      Wide Dynamic Range Goniometric Radiometer for characterizing the angular radiation irradiance from a fiber optic, waveguide, laser diode, VCSEL or LED between 320nm and 1100nm wavelength. Full 3D capability.

      Request a Quote

    Software

    FAQ

    I have just reloaded my LD8900 software onto a new computer and now the system doesn't work. It says that the signal is saturated, even when there is no light input.

    There are two different models of the LD8900 Goniometric Radiometer (far-field profiler), the LD8900 and LD8900R. The former is an 8-bit system and the latter a 16-bit and they have different controller cards and software. If you have both systems in your facility be sure that you are loading the correct software type for the instrument you are trying to operate. Mixing either the software or the controller PCBs for these will result in this non-performance symptom. Make sure that you get the correct software for your system—16-bit LD8900R for the LD8900R or 8-bit LD8900 for the LD8900.

    Close

    Videos

    Factors to Consider When Choosing a Laser Beam Profiling System Factors to Consider When Choosing a Laser Beam Profiling System
    Why Measure Your Laser Beam? Why Measure Your Laser Beam? Why Measure Your Laser Beam?

    This tutorial is presented by Ophir-Spiricon sales engineers - the experts in the field of measuring lasers and in helping you get the most out of your laser beam.

    If you can't see the video please click here
    Fundamentals of Laser Measurement & Beam Profiling Fundamentals of Laser Measurement & Beam Profiling Fundamentals of Laser Measurement & Beam Profiling

    Is your laser's beam profile shaped correctly for your application?
    This video teaches the fundamentals of laser beam profiles and discusses the benefits of profiling your laser beam.
    Several case studies are presented showing before and after laser beam profiles.

    If you can't see the video please click here
    About Ophir-Spiricon About Ophir-Spiricon About Ophir-Spiricon

    Ophir-Spiricon is the world leader in laser beam measurement systems, from power and energy meters and sensors to spatial beam profiling. This video introduces our company and the state-of-the-art award winning products that help you get the most from your laser.

    If you can't see the video please click here

    What are the four things you need to know when selecting a laser beam profiling system? Learn from Ophir-Spiricon's sales engineers - the experts in the field of measuring lasers - what you need to know to get the most out of your laser beam.

    Tutorials and Articles

    Mode-Field Diameter and “Spot Size” Measurements of Lensed and Tapered Specialty Fibers

    By Jeffrey L. Guttman, Ph.D., Director of Engineering, Ophir-Spiricon Read more...

    Measuring Divergence of Custom Optical Fibers

    By Jeffrey L. Guttman, PhD, Director of Technology, Ophir-Spiricon, LLC Read more...

    Accessories

    Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.
    • Pulsed InGaAs Option

      PH00185

      Failsafe operation for pulsed sources operating at repetition rates >10kHz with pulse widths >500ns. For operation below 10kHz, there are possible gain saturation states, dependent on repetition rate, pulse width, and source power. Consult the factory when operating under these conditions for failure mode assessment. When questionable, pulsed source operation should be verified against CW operation.

    • Pulsed InGaAs Upgrade Option

      PH00186

      Pulsed Upgrade Option to an existing Goniometric Radiometer InGaAs system. Failsafe operation for pulsed sources operating at repetition rates >10kHz with pulse widths >500ns. For operation below 10kHz, there are possible gain saturation states, dependent on repetition rate, pulse width, and source power. Consult the factory when operating under these conditions for failure mode assessment. When questionable, pulse source operation should be verified against CW operation. Includes software upgrade. Contact Factory for details.

    • PCI Controller Upgrade

      PH00187

      Interface to allow use with standard PCI interface of desktop PC. Includes an interface box for 9180 controller card, PCI Interface card and cable, and factory calibration and realignment. System should be returned to Photon for installation. Includes software upgrade.

    • Optional Mount of User Device -LD 8900 Mount

      PH00181

      Photon will provide one semi-custom mount of customer's laser diode device. Submit device particulars for specific quote. With this option, the instrument can be used immediately and provides one example test fixture.

    • LD8900 Software Viewer

      PH00182

      Goniometric Radiometer Software Viewer for LD8900 models (8-bit). Allows users to open, review and re-analyze files that are saved using any PC computer. The Viewer has all the data processing features of the software. You can read files saved.

    • LD8900R Software Viewer

      PH00439

      Goniometric Radiometer Software Viewer for LD8900R models (16-bit). Allows users to open, review and re-analyze files that are saved using any PC computer. The Viewer has all the data processing features of the software. You can read files saved.

    • Fiber Mount - /FC

      PH00189

      Plate and mount for a single mode fiber with FC connector. Label on plate includes reference distance between source and datum plane.

    • Fiber Mount - /SC

      PH00190

      Plate and mount for a single mode fiber with SC connector. Label on plate includes reference distance between source and datum plane.

    • Fiber Mount - /ST

      PH00191

      Plate and mount for a single mode fiber with ST connector. Label on plate includes reference distance between source and datum plane.

    • Fiber Mount -/BF

      PH00192

      Plate and mount for a single mode fiber without connector. Label on plate includes reference distance between source and datum plane.

    • Option to Fiber Mount /BF - /Ribbon

      PH00193

      Optional 4-Fiber Ribbon Cartridge for the Fiber Mount /BF (Bare Fiber). Requires /BF.

    • NIST Reference Standard

      PH00188

      N.A. Reference Standard: traceable to NIST for use with Goniometric Radiometer/Far-Field profilers; i.e. LD8900 and/or LD8900R. Data provided: N.A. and Angular Widths at 50%, 13.5% and 5% clip levels, with standard deviation [with a recorded, exact source to aperture distance]. NIST reference standard includes: LD source Single Mode Test Fiber Required Mounting Plate in a storage case.